Installation and connection en
9
Adjacent units
Any adjacent units must not be made of flammable
materials. The fronts of any adjacent units must be heat-
resistant up to at least 90 °C. If the appliance is
installed very close to any other units, the minimum
clearances given in the figure must be maintained.
Wall fixing
To prevent the cooker from tipping over, you must fix it
to the wall using the enclosed bracket. Please observe
the installation instructions for fixing the oven to the
wall.
Electrical connection
The appliance must only be connected to the power
supply by a licensed professional. The appliance must
be installed in accordance with the most recent IEE
guidelines (Institute of Electrical Engineers). The
appliance may be damaged if incorrectly connected.
Make sure the voltage of the power supply corresponds
to the specified value on the rating plate.
Ensure that the power supply is properly earthed and
that the fuse and the wiring and piping system in the
building is sufficiently dimensioned for the electrical
power of the appliance.
Observe the following points when routing the service
cable:
Do not pinch or squeeze the cable.
Keep the cable away from sharp edges.
Do not bring the cable into contact with parts that
can reach temperatures of more than 50 °C above
room temperature.
:Warning – Danger of death!
There is a risk of electric shock if you touch live
components.
Always make sure your hands are dry when you
touch or hold the mains plug.
Only pull out the mains cable by taking hold of the
plug and removing the plug; never pull it out by the
mains cable itself, as this could damage it.
Never unplug the mains plug when the appliance is
in operation.
Please note the following information and ensure that:
Notes
The mains plug fits the socket.
The cable cross section is adequate.
The earthing system is properly installed.
The mains cable is only replaced by a qualified
electrician (if this is necessary).Spare mains cables
can be ordered from our after-sales service.
No power strips/multi-way connectors or extension
cables are used.
If using a residual current device, only use one that
bears the mark z.
The presence of this mark is the only way to be sure
that it fulfils all the applicable regulations.
The mains plug can be accessed at all times.
The mains cable is not kinked, crushed, modified or
severed.
The mains cable does not come into contact with
heat sources.
The electric wires have the following colours.
Connecting the appliance
The appliance belongs to protection class 1 and must
only be operated with a protective earth connection.
The appliance must be disconnected from the power
supply whenever installation work is being carried out.
The appliance must only be connected using the power
cable provided.
When the appliance is installed, protection must be
provided against accidental contact in the future.
The appliance must only be connected to the mains
electricity supply by a specialist. This specialist must be
aware of and comply with the requirements stipulated
by the local energy supply company.
Any damage caused by the appliance being incorrectly
connected is not covered by the guarantee.
Caution!
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Power cable without an earthed safety plug
The wiring must have an isolating switch with a contact
gap of at least 3 mm. Identify the phase and neutral
wires ("third wire") in the mains socket. The appliance
may be damaged if it is not connected correctly.
The mains power cable must be connected as shown in
the connection diagram.
The power cable must be H05 VV-F or H05 V2V2-F or
higher.
Note: The appliance comes delivered configured for
connection to 3 phases. The power circuit must be
configured to 20 A.
PLQ
PLQ

PLQ
PLQ
PLQ
Explanatory notes
Green and yellow
Earth <
Blue Neutral wire
Brown, black and grey Phase