User Manual - Page 150

For 212X 2019 LBT1050A-U.

Loading ...
Loading ...
Loading ...
Pre-operation checks
143
(1) Start the engines. (See page 145 for in-
formation on starting the engines.)
(2) Pull the engine shut-off cord (lanyard) to
remove the clip from the engine shut-off
switch to make sure that the engines
stop immediately.
(3) Make sure that the engines cannot be
started with the clip removed from the
engine shut-off switch.
1 Engine shut-off switch
2 Clip
Cooling water pilot outlet check
Check that water comes out from the pilot
outlets while the engines are running in the
water. If water is not circulating, something
may be clogging the intake grates. Refer to
“Jet pump clean-out procedure” on page
183.
TIP:
It may take up to 20 seconds for water to
reach the pilot outlets when first launching
the boat. The amount and force of the exiting
water will vary with engine speed.
NOTICE
A continuous flow of water from the pilot
outlets shows that water is flowing
through the engine cooling water passag-
es. If water is not flowing out of the pilot
outlets during operation, do not continue
to run the engines. Overheating and seri-
ous damage could occur. (See “Engine
overheat warning system” on page 55, 91
for more information.)
Fuel level check
Check the amount of fuel remaining in the
fuel tank using the fuel level bar graph on the
multi-function display.
AR210 / SX210
1 Fuel level bar graph
1
2
am10:27
FUEL
100
%
12.3V
MP
H
0
0.3 Avg MPG
1
SportsBoat_F3R12.book Page 143 Thursday, June 21, 2018 10:45 AM
Loading ...
Loading ...
Loading ...