Instructions for the installer
24
Installation with the flexible hose must be carried out so that the length of the
piping does not exceed 2 metres fully extended; make sure that the hoses do
not come into contact with moving parts and that they are not crushed in any
way.
6.6 Connection to liquid gas
Use a pressure regulator and make the connection on the gas cylinder following
the guidelines established by the regulations in force. Make sure that the feed
pressure complies with the values indicated in the table at point “9.2 Burner and
nozzle characteristics table”.
6.7 Room ventilation
Caution – Caution – This hob may only be installed and operated in rooms
permanently ventilated in accordance with current regulations. For proper
operation of a gas appliance it is essential for the air necessary for combustion
of the gas to be able to flow naturally into the room. Air must flow directly into the
room through openings in its outside walls. This (these) opening (s) must have a
free passage cross-section of at least 100 cm2, or 200 cm2 for appliances not
equipped with gas safety device. These openings must be constructed so that
they cannot be obstructed indoors or outdoors, and should preferably be close
to the floor on the side opposite to the combustion gas discharge point. If it is not
possible to make the openings in the room where the cooker is installed, the
necessary air may be taken from an adjoining room, proveded it is not a
bedroom or a room with fire risk.
Australia - the hob must be installed in accordance with AS 5601.1 ventilation
requirements
6.8 Combustion gas discharge
Combustion gases may be discharged by means of hoods connected to a flue
with reliable natural draught, or a fan extraction system. An effective extraction
system requires careful design by an authorised specialist, and must comply
with the regulation distances and positions. After installation, the engineer must
issue a certificate of compliance.