MRF-350 BASE STATION
Page 11
Programming For Multiple Equipment Locations
You can operate up to 15 different equipment locations, each with an MRF-
350 assigned a unique Receiver ID#. You program each of your remotes to
talk to the equipment locations you want by assigning each of your devices
to a receiver. First, you must add and name your receivers for the locations
they are placed in:
Step 1 - Open the RF Setup Window in MX Editor
The RF Setup window opens after selecting RF Control from the Program
Menu.
Step 2 - Reveal the Receiver settings
Extend the RF Setup window by clicking on the
Receivers button of the RF setup window.
Step 3 - Add, Name and Assign Receiver ID#
Using the controls at the bottom extended portion of the RF Control win-
dow, add new receivers and rename them for the equipment location.
Step 4 - Save and Download to your
remote.
You may rename the
Default receiver to
something more
descriptive by clicking
on the Rename button.
Add new receivers
by clicking on the
Add button.
Delete receivers by
selecting them first
by clicking on their
Name, then clicking
the Delete button.
Assign the correct Receiver
ID# for each LOCATION by
clicking on the desired CELL
and selecting the ID# you
want from the pull down list.
Each LOCATION should have
a unique ID#. It is ok to
install multiple MRF-350’s in
one location.