Power Supply Cord Connection
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL Jisted strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1, Attach power supply cord
strain relief
-=-=----==='- A
Remove the screws from a 3/4" (19 mm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections (C) into the hole below the terminal block opening
(B) so that one tab is pointing up (A) and the other is pointing
down (D), and hold in place. Tighten strain relief screws just
enough to hold the two clamp sections (C) together.
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down
f_
2. Attach power supply cord
to strain relief
-- ,m
Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the strain
relief. The strain relief should have a tight fit with the dryer
cabinet and be in a horizontal position. Do not further tighten
strain relief screws at this point.
4=wire Power Supply Cord Connection
iMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of
3-wire connections.
4-wire receptacle
(NEMA type 14-30R)
4=prong plug
Spade terminals
with upturned ends
Ring terminals
11