Installation
19
EN
3. Additional requirements for
Freestanding and Elevated Cooking
Appliaces – (Measurements D & E)
Where D, the distance from the
periphery of the nearest burner to a
horizontal combustible surface is less
than 200 mm, then E shall be 10 mm or
more, or the horizontal surface shall be
above the trivet. See insets above.
Notes
1. Requirement 3 does not apply to a
freestanding or elevated cooking
appliance which is designed to prevent
flames or the cooking vessels from
extending beyond the periphery of the
appliance.
2. The ‘cooking surface area’ is defined as
that part of the appliance where cooking
normally takes place and does not
include those parts of the appliance
containing control knobs.
3. For definition of hob, see Clause 1.4.64.
4. For definition of trivet, see Clause
1.4.109.
5. Consideration is to be given to window
treatments when located near cooking
appliances. See Clause 5.3.4.
5.2 Safety instructions
Veneers, adhesives or plastic coatings on
adjacent furniture should be temperature-
resistant (>90°C), otherwise they might
warp over time.
The minimum clearances must also be
respected for the edges of the hob on the
back as indicated in the mounting
illustrations.
The appliance connection point
shall be accessible with the
appliance installed.
Heat production during appliance
operation
Risk of fire
• Check that the carcase material is heat
resistant.
• Check that the carcase has the required
openings.
The minimum clearance between a
ventilation hood and the cooking
surface must be at least the
distance indicated in the ventilation
hood installation instructions.