Power Supply Cord
Electrical Connection
Direct Wire
Fire Hazard
Use a new UL approved 30 amp
power supply cord.
Use a UL approved strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or center
wire) to center terminal (silver).
Ground wire (green or bare wire)
must be connected to green ground
connector.
Connect remaining 2 supply wires to
remaining 2 terminals (gold).
Securely tighten all electrical
connections.
Failure to do so can result in death,
fire, or electrical shock.
1. Disconnect power,
2. Remove the hold-down screw and
terminal block cover.
1 2 3 4
1 Terminal block cover
2. Extemal ground connector
3. Center', silver-colored terminal-block
screw
4. Hold-down screw location
5. Neutral grounding wire (green/yellow)
6 Hole below terminal block opening
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL approved strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or center
wire) to center terminal (silver).
Ground wire (green or bare wire) must
be connected to green ground
connector.
Connect remaining 2 supply wires
to remaining 2 terminals (gold).
Securely tighten all electrical
connections.
Failure to do so can result in death,
fire, or electrical shock.
3.
Assemble a 3_4in, (1,9 cm) UL
approved strain relief (UL marking on
strain relief) into the hole below the
terminal block opening, Tighten strain
relief screws just enough to hold the
two clamp sections together, Put
power supply cord through the strain
relief, The strain relief should have a
tight fit with the dryer cabinet and be
in a horizontal position.
4. Now complete installation following
instructions for your type of electri-
cal connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
10