Silver colored Terminal Colored
Terminal
wire
Wire
Terminal
Block
wire
A strainr_ I-I/8" Dia.
Direct
supplied by the user Connection
must be installed at To 240 V Hole. Punch
this location receptacle out knockout
Figure 3 for I-3/8" Dia.
Cord Kit Hole
Four Conductor Wire Connection to Range
(mobile homes)
I. Remove the 3 screws at the lower end of the rear
wire cover, then raise the lower end of the rear wire
cover (accesscover) upward to expose range
terminal connection block (see Figure 2).
2. Remove the 3 loose nuts (after you remove the
rubber band) on the terminal block using a 3/8" nut
driver or socket.
3. Remove the ground strap from the terminal block
and from the appliance frame.
4. Connect the ground wire (green) of the copper
power supply cord to the frame of the appliance
with the ground screw, using the hole in the frame
where the ground strap was removed (see Figure 4).
5. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal).
6. Replace the 3 nuts on the terminal block (see Figure
4).
7. Lower the terminal cover and replace the 3 screws.
Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use flexible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L listed strain-relief at each end of the
cable. At the appliance end, the cable goes through the
Direct Connection Hole (see Figure 4) on the Cord
Mounting Plate. Wire sizes (copper wire only) and
connections must conform to the rating of the appliance.
Direct
Connection
Hole. Punch
out knockout
for 1-3/8" Dia.
Cord Kit Hole
A strainrelief
supplied by the user
must be installed at 240 V receptacle
this location
NOTE: Besure to remove the supplied f/l
grounding strap :_
Figure 4
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire
(see Figure 5):
I. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
connect appliance and residence cable wires as
shown in figure 5.
Cable from
Residence
White Wire
(Neutral)
Black
Wires-
Box
White Wire
(Neutral)
Green U.L.-listed
(or Bare Copper) Conduit
Wire Cable from Connector
Range (or CSA listed)
Figure 5
3-Wire (Grounded Neutral) Electrical System
(ExampJe: Junction Box)