Appliance Rating Watts Minimum Conductor Size, AWG
120V / 208V L1 and L2 Neutral Ground
Conductors Conductor Conductor
0-3120 16 16 14
3121-3900 16 16 12
3901-4160 14 16 12
4161-5200 14 16 10
5201-5570 12 16 10
5571-7430 12 14 10
7431-7800 12 12 10
7801-12500 10 12 10
12501-14500 8 12 10
Appliance Rating Watts Minimum Conductor Size, AWG
120V / 240V L1 and L2 Neutral Ground
Conductors Conductor Conductor
0-3600 16 16 14
3601-4500 16 16 12
4501-4800 14 16 12
4801-6000 14 16 10
6001-6425 12 16 10
6426-8749 12 12 10
8750-14500 10 12 10
14501-16500 10 10 10
16501-24000 8 10 8
For mobile homes, new installations or recreational
vehicles, use only a power supply kit designed for a
range at 125V/250V 40A. Cord must have either 3
(when local code permits grounding through neutral) or 4
conductors. Terminal on end of wires must be either
closed loop or open spade lug with upturned ends. Cord
must have strain-releif clamp. See chart for the minimum
wire size (general UL listing, local code may differ).
Range Connection Opening Size Chart
Refer to chart below for proper range connection opening size
and power supply cord kit ampere rating information. See serial
plate on range for kilowatt rating data.
See Serial Plate on Range
for KW Rating
120/240 Volts 120/208 Volts
8.8-16.5Kw 7.9-12.5 Kw
16.6-22.5Kw 12.6-18.5 Kw
Diameter (inches) of Range
Minimum Connection Opening
Cord kit
Ampere Direct
Rating Cord Kit Connection
40 Amp 1-3/8 in. 1-1/8 in.
50 Amp 1-3/8 in. 1-3/8 in.
NOTE: Electric Slide-in Range is shipped from factory with
I-I/8" dia. hole as shown on figure 3. If a larger hole is
required, punch out the knockout.
Risk of fire or electrical shock exists if
an incorrect size range cord kit is used, the
InstalJation Instructions are not foJJowed, or the
strain reJief bracket is discarded.
Do not loosen the nuts which secure
the factory-installed range wiring to terminaJ block
while connecting range. ElectricaJ faiJure or Joss of
eJectricaJ connection may occur.
Electrical Connection to the Range
appliance is manufactured with the neutral terminal
connected to the frame.
Electrical Shock Hazard
* Electrical ground is required on this appliance.
, Do not connect to the electrical suppJy until
appliance is permanently grounded.
, Disconnect power to the circuit breaker or fuse
box before making the electrical connection.
* This appliance must be connected to a
grounded, metallic, permanent wiring system,
or a grounding connector should be connected
to the grounding terminal or wire lead on the
appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.
Three Conductor Wire Connection to Range
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power supply
cord (see Figure 3):
I. Remove the 3 screws at the lower end of the rear
wire cover, then bend the lower end of the rear wire
cover (accesscover) upward to expose range
terminal connection block (see Figure 2).
BEND REAR WIRE COVER HERE
FOR ACCESS TO TERMINAL BLOCK
Figure 2
2. Remove the 3 loose nuts (after you remove the
rubber band) on the terminal block using 3/8" nut
driver or socket.
3. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal).
4. Replace the 3 nuts on the terminal block (see Figure
3).
5. Lower the terminal cover and replace the 3 screws.