3. Remove the metal grease filter and secure the blower
housing with two screws in the bottom holes located in the
rear of the blower.
Glass Mantle Installation
1. Place the glass mantle onto the hood.
2. Connect glass mantle to range hood with the 2 glass
mounting brackets and four 4 x 8 mm screws.
Connect Vent System
Vented Installation Only
1. Fit vent system over transition piece.
2. Seal connection with clamps.
3. Check that backdraft dampers work properly.
For Non-vented (Recirculating) Installation:
1. Assemble the 3 parts of the deflector with 2 - 3.5 x 9.5 mm
screws provided. The assembled deflector should be sized to
fit the width of the vent cover bracket installed earlier.
2. Connect the deflector to the vent cover bracket using 4 - 3.5
x 9.5 mm screws provided.
3. Measure the length of 8" (20.3 cm) round vent (not provided)
needed to connect the transition to the deflector.
NOTE: Vent should fit inside deflector a minimum of
1" (2.5 cm)
4. Install vent between the transition and the deflector.
5. Seal connection with clamps.
6. Check that backdraft dampers work properly.