To Remove Metal Grease Filters
1. Turn off fan and lights. Check that halogen lamp is cool.
2. Remove the filter holder frame and grease filter using a flat-
blade screwdriver to turn the grease filter release screws 90°
counterclockwise.
To Replace Metal Grease Filter
1. Turn off fan and lights. Check that halogen lamp is cool.
2. Remove the filter holder frame and grease filter using a flat-
blade screwdriver to turn the grease filter release screws 90°
counterclockwise.
3. Replace grease filter and filter holder frame into range hood.
Align the grease filter release screw and use a flat-blade
screwdriver to turn the grease filter release screws 90°
clockwise to lock in place.
Charcoal Filters - For Non-Vented (recirculating)
Installations
NOTE: After approximately 3 years of use the charcoal filter
should be replaced. To order a replacement Charcoal Filter Kit,
see the “Assistance or Service” section.
The charcoal filters can be cleaned and reactivated. Clean the
filter in the dishwasher using normal detergent and choosing the
highest temperature setting.
To reactivate the filter, the filter should be dried in an oven for
10 minutes with a maximum temperature of 210°F (100°C).
To Replace Charcoal Filters
1. Turn fan and lights off. Check that halogen lamp is cool.
2. Remove the metal grease filters. See “Metal Grease Filters”
section.
3. Remove the upper and side lock springs.
4. Clean or discard the charcoal filter.
5. Install cleaned or replacement filter.
Replacing a Halogen Lamp
Turn off the range hood and allow the halogen lamp to cool. To
avoid damage or decreasing the life of the new bulb, do not
touch bulb with bare fingers. Replace bulb, using tissue or
wearing cotton gloves to handle bulb.
If new lights do not operate, make sure the lamps are inserted
correctly before calling service.
1. Disconnect power.
2. Use a flat-blade screwdriver and gently pry the light cover
loose.
3. Remove the lamp and replace with a 12-volt, 20-watt
maximum, halogen lamp made for a G-4 base.
4. Replace the light cover.
5. Reconnect power.