9
ONHr
AFTER
SIMPLE
˚C
˚C
OFF
Hr
AFTER
SIMPLE
SIMPLE
At 3 hours after
timer start
At Timer Start
Display shows the tim-
ers ON setting (hours
remaining to ON).
Display changes to
show the timers OFF
setting (hours remain-
ing to OFF). The time
displayed is OFF set-
ting (7 hours) ON set-
ting (3 hours) = 4 hours.
At 7 hours after
timer start
The air conditioner
goes off, and will re-
main off until some-
one restarts it.
˚C
˚C
OFF
Hr
AFTER
SIMPLE
ONHr
AFTER
SIMPLE
˚C
˚C
SIMPLE
At 2 hours after
timer start
At Timer Start
At 5 hours after
timer start
Display shows the tim-
ers OFF setting (hours
remaining to OFF).
Display changes to
show the timers ON
setting (hours remain-
ing to ON). The time
displayed is ON setting
(5 hours) OFF setting
(2 hours) = 3 hours.
The air conditioner
comes on, and will
continue to run until
someone turns it off.
Examples
If ON and OFF times have both been set at the simple timer, operation and
display are as indicated below.
Example 1:
Start the timer, with ON time set sooner than OFF time
ON Setting: 3 hours
OFF Setting: 7 hours
2. Operation
Example 2:
Start the timer, with OFF time is sooner than ON time
ON Setting: 5 hours
OFF Setting: 2 hours
2.10.3. Using the Auto Off Timer
This timer begins countdown when the air conditioner starts, and shuts
the air conditioner off when the set time has elapsed.
Available settings run from 30 minutes to 4 hours, in 30-minute intervals.
Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same time.
*2. The Auto Off timer will not operate when any of the following conditions is
in effect.
The timer is off; the system is in malfunction state; a test run is in progress;
the remote controller is undergoing self-check or remote controller check;
the user is in the process of selecting a function; the user is in the process
of setting the timer; the system is under central control. (Under these con-
ditions, On/Off operation is prohibited.)
AFTER OFF
AUTO OFF
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK DAY
MONITOR/SET
CLOCK
ON/OFF
2A9
4
B
ss
ss
sHow to Set the Auto Off Timer
1. Be sure that you are at a standard control screen, and that the Auto
Off timer indicator is visible in the display (at 1).
When something other than the Auto Off Timer is displayed, set it to
AUTO OFF TIMER using the function selection of remote controller
(see 2.13. [4]3 (3)).
2. Hold down the Timer Menu button B for 3 seconds, so that the Set
Up appears on the screen (at 2).
(Note that each press of the button toggles the display between Set
Up and Monitor.)
3. Press the appropriate Set Time button A as necessary to set the
OFF time (at 3).
4. Press the Filter button 4 to lock in the setting.
Note:
Your entry will be cancelled if you press the Mode (Return) button 2
before pressing the Filter
button 4.
AFTER OFF
AUTO OFF
3
1
2
Timer Setting
Loading ...
Loading ...
Loading ...