Loading ...
Loading ...
Loading ...
14
B
A
D
C
Caution:
Always turn off the power, first on the remote controller and then
the main switch, before cleaning or servicing the unit.
When installing or removing the filter or the intake grille, do not
stand on an unsteady surface. You may fall and injure yourself. Be
also careful not to let dust fall into your eyes.
Dirty or clogged filters block the airflow and reduce efficiency. Very dirty
filters can damage the air-conditioner itself.
Intake grille removal
1Pull the catch on the intake grille in the direction indicated by the arrow
and it should open.
2Unhook the hinges to remove the intake grille from the grille.
Filter removal
1Open the intake grille.
2Release the catch on the center edge of the intake grille and pull the
filter forward to remove the filter.
A Catch B Grille C Intake grille D Filter
2. Operation
[4]4. Display change setting
(1) Temperature display °C/°F setting
To switch the setting, press the [ ON/OFF] button D.
1 °C : The temperature unit °C is used.
2 °F : The temperature unit °F is used.
(2) Suction air temperature display setting
To switch the setting, press the [ ON/OFF] button D.
1 ON : The suction air temperature is displayed.
2 OFF : The suction air temperature is not displayed.
(3) Automatic cooling/heating display setting
To switch the setting, press the [ ON/OFF] button D.
1 ON : One of Automatic cooling and Automatic heating is displayed under the automatic mode is running.
2 OFF : Only Automatic is displayed under the automatic mode.
2.14. Emergency operation
[For wireless remote controller]
When the remote controller cannot be used
When the batteries of the remote controller run out or the remote controller
malfunctions, the emergency operation can be done using the emergency
buttons on the grille.
ADEFROST/STAND BY lamp
BOperation lamp
CEmergency operation switch (heating)
DEmergency operation switch (cooling)
EReceiver
Starting operation
To operate the cooling mode, press the button D.
To operate the heating mode, press the button C.
Note:
Details of emergency mode are as shown below.
Details of EMERGENCY MODE are as shown below.
Operation mode COOL HEAT
Set temperature 24°C24°C
Fan speed High High
Airflow direction Horizontal 30° Downward 70°
Stopping operation
To stop operation, press the button D or the button C.
A B C D E
SLP-2AL (For SLZ-KA25/KA35/KA50VAL)
3. Care and cleaning
Loading ...
Loading ...