48-, 78-, 115-Can Beer and Beverage Cooler
www.insigniaproducts.com
7 Place the bottom left corner of the door onto the lower hinge, then
install the top hinge onto cabinet. Make sure the door is level and it
seals properly against cabinet, then securely fasten the three screws.
8 Snap the top cap back onto the hinge.
Auto Defrosting
During the auto defrosting process, the compressor shuts down and the
frost melts naturally.
When either of the following happens, the process ends and the
compressor starts again:
The inner temperature is above 41º F (5º C).
Defrosting time is longer than 60 min.
The temperature fluctuation during the defrosting process is within 7.2º F
(4º C).
In addition, when the inner temperature setting is above 41º F (5º C), the
compressor shuts down every six hours. However, as soon as the sensor
detects the inner temperature is above 41º F (5ºC), the compressor starts
immediately. The temperature fluctuation during this period is within
1.8º F (1º C).