27
GB
9.1. PartsList
9.2. Installationprocedure
9.3. WhenconnectingtheDRED.
1
Bandx1
CN3D
CN3S
1
3
1
3
RD
BN
YE
WH
1
2
3
C
Common
DRM3
DRM2
DRM1
DRED (Demand controller)
Terminal block
Outdoor unit control board
Input:12VDC, 1mA
DipSW setting
SW5-1 SW9-2 Function
OFF OFF Silent Mode
ON Existing Demand Mode
ON OFF Silent Mode
ON Demand Response Mode (DRM)
●Theunitissettodefaultsettingsasintheshadedarea(Demand
ResponseMode(DRM)(SW5-1:ON,SW9-2:ON))whenshipped.
●Refertotheservicemanualfordetailsaboutthefunctionsofthe
unit other than Demand Response Mode (DRM).
A
DRMcablex1
M
i
n
.
1
0
0
m
m
●ACCESSORIES
(Check the following parts before installation.)
●PARTSTOBEPROVIDEDATYOURSITE
PUMY-SP•VKMD
PUMY-SP•YKMD
9. Installationandoperationmanualfordemandresponse(DRED)
Model
Wirespecications
Demand control signal transmission cable *1
Outdoor unit 0.5 - 1.5 mm²
*1 UsewiresinconformitywithdesignAS/NZS5000.2.
1
Band
Fix the DRM cable
with lead wire.
A
DRM cable
Pass the DRM cable between TB1
and TB1B.
TBD1
TB1
TB1B
TBD1
A
DRM cable
Valve bed Valve bed
Fix by clamp
●ThebandisnotusedforthePUMY-SP•VKMD.
Fix by clamp
RG79Y960H01.indb 27 2018/02/09 14:31:14