122
21. Service Data
Service data provided are based on the air conditioner running under rated frequency during forced cooling / forced
heating mode.
21.1 Cool Mode Outdoor Air Temperature Characteristic
Condition
- Indoor room temperature: 80°F Dry Bulb/67°F Wet Bulb
- Unit setting: Standard piping length, forced cooling at 60.8°F, Hi fan
- Compressor frequency: Rated for cooling operation
- Piping length: 24.6ft
- Voltage: 230V
21.1.1 CS-E9RKUAW CU-E9RKUA
59.0
59.5
60.0
60.5
61.0
61.5
62.0
62.5
63.0
63.5
64.0
64.5
-4 6 162636465666768696106116
Outlet Air
(°F)
Outdoor Air Temperature (°F)
230
1.5
2.0
2.5
3.0
3.5
4.0
-4 6 162636465666768696106116
Current
(A)
Outdoor Air Temperature (°F)
134.0
136.0
138.0
140.0
142.0
144.0
146.0
148.0
150.0
152.0
-4 6 162636465666768696106116
Gas Side Piping
Pressure (PSI)
Outdoor Air Temperature (°F)