Loading ...
Loading ...
Loading ...
111
WARNING
High Voltage is generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding with
repair work. Failure to heed this caution may result in electric shocks.
19.2 CS-E18RKUAW CS-E24RKUAW
19.2.1 Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal
Procedures
19.2.1.1 To remove front grille
Figure 1
19.2.1.2 To remove power electronic controller
Figure 2
Figure 3 Figure 4
1. Lift to open the horizontal vane
and intake grille gently.
2. Remove 3 caps and 4 screws at the
bottom of the discharge vane.
3. Hold both sides of the front
grille and remove it by pulling
up and toward you gently.
4. Remove the eco sensor complete by screw.
5. Remove the control
board cover by
releasing the 2 hooks.
2 Hooks (left hand side)
7. Detach the CN-DISP
connector then remove
the indicator complete.
10. Detach 3 or 4 connectors as labeled from
the electronic controller. Then pull out
main controller gently
9. Pull out the main
electronic controller and
power electronic
controller halfway.
8. Remove screw to
remove terminal board
complete.
6. Detach the Earth wire
CN-RMT
CN-FM
CN-STM1
CN-STM2
CN-MSENS
CN-TH
CN-DISP
Loading ...
Loading ...
Loading ...