Loading ...
Loading ...
Loading ...
31
LP Conversion Instructions
With the installation of this conversion kit,
the cooktop should operate on LP gas at 10
of water column pressure.
The pressure regulator must be connected in series
with the manifold of the cooktop and must remain
in series with the supply line. For proper operation,
the maximum inlet pressure to the regulator must
be no more than 14 water column pressure for
LP gas.
When checking the regulator, the inlet pressure
must be at least 1 greater than the regulator output
setting. If the regulator is set for 10 of water column
pressure, the inlet pressure must be at least 11.
IMPORTANT Disconnect the cooktop and
the individual shut-off valve from the gas supply piping
system during any pressure testing of that system at test
pressures greater than 1/2 psig. Isolate the cooktop from
the gas supply piping system by closing the individual
manual shut-off valve to the cooktop during any pressure
testing of the gas supply piping system at test pressures
equal to or greater than 1/2 psig.
GAS SUPPLY
BEFORE YOU BEGIN, TURN OFF THE GAS SUPPLY AT
THE SHUT-OFF VALVE. DISCONNECT THE ELECTRICAL
SUPPLY FROM THE COOKTOP.
TURN OFF GAS AND
ELECTRIC SUPPLY
CONVERT THE PRESSURE REGULATOR
Locate the pressure regulator under the front
of the cooktop.
A
1
Remove the nut from the pressure regulator with
an adjustable wrench.
B
Remove the plastic pin from the inside of the nut,
turn the pin 180° and snap the pin back into the nut.
C
Re-install the nut onto the regulator.
Apply the LP Conversion label next to the Rating Plate.
E
D
Shut-off valve
Electrical supply
Nut
Natural gas
LP gas
Nut
Natural gas LP gas
Loading ...
Loading ...
Loading ...