13
CONVERSIONS
8) UNIVERSAL LP GAS TO NATURAL GAS
CONVERSION PROCEDURE
Appliance models: Gas Vitroceramic hotplate
models:
1. Remove each burner cap and burner skirt.
2. Remove the Universal LP Gas main injector with
a 7 mm/VF tube spanner and replace with the
appropriate size Natural Gas injector for each
burner. The following injector sizes are required for
Natural Gas:
Burner Main injector
Wok 1.75 B mm
Rapid 1.55 mm
Semi Rapid Reduced 1.05 mm
Semi Rapid 1.20 mm
Auxiliary 0.90 mm
3. Shut off gas supply to the appliance.
4. Disconnect gas inlet pipe from the Universal LP
Gas test point inlet fitting.
5. Remove the Universal LP Gas test point inlet
fitting from the appliance.
6. Fit the Natural Gas Regulator supplied in the
conversion kit.
7. Connect the gas supply to the Regulator.
8. Check for gas leaks. Do not use a naked flame
to check for gas leaks.
9. Adjust the gas pressure to 1.00 kPa.
10. Remove the control knob, with a thin shaft blade
screwdriver down the centre of each gas valve
shaft, screw the by-pass injector anti-clockwise.
Test the appliance on both high and low flame for
each burner. If the burner fails to remain alight or
the flame is not stable on the simmer setting, adjust
the by-pass screw, until flame is stable.
11. If not already removed, remove the β€œOnly for
use with Universal LP Gas” label adhered to the
bottom panel near the gas connection.
12. Fit the new data label included in the gas
conversion kit.
9) NATURAL GAS TO UNIVERSAL LP GAS
CONVERSION PROCEDURE
Appliance models: Gas Vitroceramic hotplate
models:
1. Remove each burner cap and burner skirt.
2. Remove the Natural Gas main injector with a 7
mm/VF tube spanner and replace with the
appropriate size Universal LP Gas main injector for
each burner. The following injector sizes are required
for Universal LP Gas:
Burner Main injector
Wok
1.00 B
mm
Rapid 0.91 mm
Semi Rapid Reduced 0.60 mm
Semi Rapid 0.70 mm
Auxiliary 0.53 mm
3. Remove the control knob, with a thin shaft blade
screwdriver down the centre of each gas valve
shaft, screw the by-pass injector fully clockwise.
4. Shut off gas supply to the appliance.
5. Disconnect gas inlet pipe from the Natural Gas
Regulator.
6. Remove the Natural Gas Regulator from the
appliance.
7. Fit the Universal LP Gas test point inlet fitting
supplied in the conversion kit.
8. Connect the gas supply to the inlet fitting.
9. Check for gas leaks. Do not use a naked flame
to check for gas leaks.
10. Adjust the gas pressure to 2.75 kPa.
11. Test the appliance on both high and low flame
for each burner and check the gas pressure. If the
burner fails to remain alight or the flame is not
stable on the simmer setting, adjust the by-pass
screw, until flame is stable.
12. If not already removed, remove the β€œOnly for
use with Natural Gas” label adhered to the bottom
panel near the gas connection.
13. Fit the new data label included in the gas
conversion kit.
Mod: OCG63FFX
3 Burners
Mod: OCG64FFX
4 Burners
Mod: OCG95FFX
5 Burners
Mod: OCG63FFX
3 Burners
Mod: OCG64FFX
4 Burners
Mod: OCG95FFX
5 Burners