TECHNICAL DATA
Burners
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven compartment
has been opened, on the left-hand
wall inside the oven.
Declared energy consumption for
Natural convection Class – heating
mode:
Table of burner and nozzle specifications
Table 1 Liquid Gas Natural Gas
Burner Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nominal Reduced (mm) (mm) *** ** (mm)
Fast
(Large)(R)
Semi Fast
(Medium)(S)
Auxiliary
(Small)(A)
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar- dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
3
51 1.00 0.4 30 50 73 71 78 95
75 1.90 0.4 30 69 138 136 104 181
100 3.00 0.7 41 87 218 214 128 286
ENERGY LABEL
and ECODESIGN
ECO
! This procedure must be performed by a qualified
technician who has been authorised by the
manufacturer.
EN
TECHNICAL DATATECHNICAL DATATECHNICAL DATATECHNICAL DATATECHNICAL DATATECHNICAL DATA
9
After installing the power cable, screw the metal cover
with three screws.