Positioning
This unit may be installed and used only in
permanently ventilated rooms according to the British
Standards Codes Of Practice: B.S. 6172/B.S. 5440,
Par. 2 and B.S. 6891 Current Editions. The following
requirements must be observed:
a. The cooker should not be installed in a bed sitting
room with a volume of less than 20m
3
. If it is installed
in a room of volume less than 5m
3
an air vent of
effective area of 100cm
2
is required, if it is installed
in a room of volume between 5m
3
and 10m
3
a
supplementary airvent area of 50cm2 is required,
if the volume exceeds 10m
3
no airvent is required.
However, if the room has a door or a window which
opens directly to the outside no air vent is required
even when the volume is between 5m
3
and 10m
3
.
b. During prolonged use of the appliance you may
consider it necessary to open a window to the
outside to improve ventilation.
This appliance must not be fitted on a platform.
The cooker is designed to fit between kitchen cabinets
spaced 500mm apart. The space either side need
only be sufficient to allow withdrawal of the cooker for
servicing. It can be used with cabinets one side or
both as well as in a corner setting. It can also be used
free-standing.
Adjacent side walls which project above hob level,
must not be nearer to the cooker than 150mm or 65mm
and should be protected by heat resistant
material. Any overhanging surface or cooker hood
should not be nearer than 750mm.
a. The cooker may be located in a kitchen, a kitchen/
diner or bed sitting room, but not in a bathroom or
shower room.
b. The hoods must be installed according to the
requirements in the hood handbook.
c. The wall in contact with the back of the cooker must
be of flameproof material.
d. The cooker is fitted with a safety chain that must be
attached to a hook, secured to the wall behind the
appliance.
Gas connection
The cooker should be connected to the gas-supply
by a gas safe registered installer. During installation
of this product it is essential to fit an approved gas
tap to isolate the supply from the appliance for the
convenience of any subsequent removal or servicing.
The appliance must not be installed behind
a decorative door in order to avoid overheating
Connection of the appliance to the gas mains or liquid
gas must be carried out according to the prescribed
regulation in force, and only after it is ascertained that it
is adaptable to the type of gas to be used. If not, follow
the instructions indicated in the paragraph headed
“Adaptation to different gas types”. On some models
the gas supply can be connected on the left or on the
right, as necessary; to change the connection, reverse
the position of the hose holder with that of the cap
and replace the gasket (supplied with the appliance).
In the case of connection to liquid gas, by tank, use
pressure regulators that conform to the regulation in
force. The gas supply must be connected to the left
of the appliance. Be sure that the hose does not pass
through the rear of the cooker touching hot parts.
Make sure the supply pressure conforms
with the values shown in the table entitled
“Caracteristics of the burners and nozzles”.
When the cooker is installed between cabinets
(recessed), the gas connection must be effected
by an approved flexible hose with bayonet fitting
(BS 669 Current Edition). The gas inlet for the
cookers is a threaded G 1/2 gas female fitting.
EN
WARNING : This operation must be perfomed
by a qualified technician
INSTALLATION TIPSINSTALLATION TIPSINSTALLATION TIPSINSTALLATION TIPSINSTALLATION TIPS
c. If there are other fuel burning appliances in the
same room, B.S.5440 Part 2 Current Edition, should,
be consulted to determine the requisite air vent.
The height of the cooker can be adjusted by means
of adjustable feet in the plinth (900mm - 915mm).
Adjust the feet by tilting the cooker from the side.
Then install the product into position.
Replacing the fuse:
When replacing a faulty fuse, a 13 amp ASTA
approved fuse to BS 1362 should always be used,
and the fuse cover re-fitted. If the fuse cover is lost,
the plug must not be used until a replacement is
obtained.
Electrial connection
Power supply voltage and frequency: 230-240V a.c.
50/60 Hz.
The supply cable must be positioned so that it
never reaches at any point a temperature 50°C
higher than the room temperature. The cable must
be routed away from the rear vents. Should you
require it, you may use a longer cable, however, you
must ensure that the cable supplied with the
appliance is replaced by one of the same
specifications in accordance with current standards
and legislation.
Your appliance is supplied with a 13 amp fused plug
that can be plugged into a 13 amp socket for
immediate use. Before using the appliance please
read the instructions below.
WARNING - THIS APPLIANCE MUST BE
EARTHED.
THE FOLLOWING OPERATIONS SHOULD BE
CARRIED OUT BY A QUALIFIED ELECTRICIAN.
Replacement fuse covers:
If a replacement fuse cover is fitted, it must be of
the correct colour as indicated by the coloured
marking or the colour that is embossed in words on
the base of the plug. Replacements can be obtained
directly from your nearest Service Depot.
7
The room containing the appliance must contain
an openable window or an acceptable alternative
such as an adjustable louvre or hinged panel
opening direct to outside air.