must be installed and connected in accordance
with current installation regulations. Particular
attention must be paid to the relevant
requirements regarding ventilation.
If the appliance is connected to liquid gas,
the regulation screw must be fastned as tightly as
possible.
IMPORTANT : When the gas cylinder or gas
container is installed, it must be properly settled
(vertical orientation).
WARNING : This operation must be perfomed
by a qualified technician
Use only flexible or rigid metal hose for gas
connection.
Connection with a rigid pipe (copper or steel)
Connection to the gas system must be carried
out in such a way as not to place any strain of
any kind on the appliance. There is an adjustable
L-shaped pipe fitting on the appliance supply
ramp and this is fitted with a seal in order to
prevent leaks. The seal must always be replaced
after rotating the pipe fitting (the seal is provided
with the appliance). The gas supply pipe fitting is
a threaded 1/2 gas cylindrical male attachment.
Connecting a flexible jointless stainless steel
pipe to a threaded attachment
The gas supply pipe fitting is a threaded 1/2 gas
cylindrical male attachment. These pipes must
be installed so that they are never longer than
2000 mm when fully extended. Once connection
has been made, make sure that the flexible metal
pipe does not touch any moving parts and is not
compressed. Only use pipes and seals that comply
with current national regulations.
IMPORTANT : If a staineless steel hose is used,
it must be installed so as not touch any moving
part of the furniture (e.g.drawer). It must pass
thorugh an area where there are no obstructions
and where it is possible to inspect it across its
entire length.
Theappliance shouldbe connectedto themain
gas supply or to a gas cylinder in compliance with
the current national regulations. Before making
the connection, make sure that the appliance is
compatible with the gas supply you wish to use.
If it is not, follow the instructions indicated in the
paragraph "Adapting to different types of gas".
After connection to the gas supply, check for
knobs from max position 1* to minimum position
2* to check flame stability.
Connection to the gas network or the gas
cylinder may be carryout using a flexible rubber
or steel hose, in accordance with current national
legislation.
ADAPTING TO DIFFERENT TYPES OF GAS
(This operation needs to be carried out by a
qualified technician.)
In order to adapt the appliance to a type of gas
other than the type for which it was manufactured
(indicatedontheratinglabel),followthededicated
steps provided after installation drawings.
ELECTRICAL WARNINGS
IMPORTANT: Information about current and
voltage consumption is provided on the rating
plate.
The rating plate is on the front edge of the
oven (visible when the door is open).
It must be possible to disconnect the appliance
from the power supply by unplugging it if
plug is accessible, or by a multi-pole switch
installed upstream of the socket in accordance
with the wiring rules and the appliance must
be earthed in conformity with national electrical
safety standards.
The power cable must be long enough to connect the appliance,
once fitted in its housing, to the main power supply. Do not pull the
power supply cable.
Do not use extension leads, multiple sockets
or adapters. The electrical components must not
be accessible to the user after installation. Do not
use the appliance when you are wet or barefoot.
Do not operate this appliance if it has a damaged
power cable or plug, if it is not working properly,
or if it has been damaged or dropped.
If the supply cord is damaged, it must
be replaced with an identical one by the
manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard -
risk of electric shock.
If the power cable needs to be replaced,
contact an authorised service centre.
WARNING: Ensure that the appliance is
switched off before replacing the lamp to avoid
the possibility of electric shock.
CLEANING AND MAINTENANCE
WARNING: Ensure that the appliance is
switched off and disconnected from the power
supply before performing any maintenance
operation; never use steam cleaning equipment -
risk of electric shock.
Do not use harsh abrasive cleaners or metal
scrapers to clean the door glass since they can
scratch the surface, which may result in shattering
of the glass.
Do not use abrasive or corrosive products,
chlorine-based cleaners or pan scourers.
Make sure the appliance has cooled down
before cleaning or performing maintenance. - risk
of burns.
WARNING: Switch off the appliance before
replacing the lamp - risk of electric shock.
To avoid damaging the electric ignition device, do not use it when
the burners are not in their housing.
Wear protective gloves for cleaning and
maintenance.
leaks in accordance with current National
Regulations and Standards in force in the country
of installation. Light up the burners and turn the