1.
Unplug the current power cord being used from the
outlet/receptacle.
2.
To disconnect and/or reconnect a new power cord
you must remove the top cover of the appliance as
shown below.
A. Remove the two T20 torx head screws.
B. Push the top cover toward the rear of the appliance
and lift up.
3.
Open the connection box toward the rear of the
appliance by removing the T20 torx head screw
fastening the cover.
4.
Remove the 4-wire power cord (as supplied):
A. Remove the 3 Philips screws (2 labeled L and one
labeled N).
B. Remove the green grounding screw PE (T20 torx).
NOTICE: Be careful not to drop the screws into the
dryer.
5.
Loosen the strain relief clamp screw (Philips head) on
rear of the connection box.
6.
Pull the old power cord out of the connection box.
7.
Install the new power cord back through the strain
relief clamp.
NOTICE: Ensure the strain relief clamp has not been
moved and its clamping screw(s) are outside the rear
of the connection box.
8.
Ensure the terminal ends are long enough and are
formed (bent) so that no part of them (wires or
terminal ends) come in contact with connection box
enclosure.
NOTICE: Use only open-end spade lugs.
9.
Ensure the terminal ends are long enough and are
formed (bent) so they will align with the terminal block
fastening locations (screw holes).
10.
Reinstall the 2 terminal block screws (Philips head) at
locations L as shown below.
11.
If the ground wire shown below from N to PE is not
part of the 3-wire cord assembly you have it must be
obtained/purchased separately and it must be
installed.
12.
Install the last terminal block screw (Philips) and 1
grounding screw (T20 torx) at locations N and PE.
13.
Tighten the strain relief screw ensuring the power cord
cannot be pulled out of the connection box but not so
tight as cut the power cord insulation.
14.
Reinstall the connection box cover making sure all
wires are routed so they do not touch any part of the
enclosure and are secure.
15.
Reinstall the appliance top cover as previously
described in “2” point above.
Integrated electrical receptacle
This appliance is equipped with a 208/240V 15A
receptacle for use ONLY with Bosch washer listed below.
9 CAUTION
Do not use this receptacle to power any other
device.
If any other electrical device is plugged into this
receptacle Bosch will assume no liability.
9 CAUTION
Use integrated electrical receptacle only for these
Bosch washer listed:
WAP24200UC, WAP24201UC, WAP24202UC,
WAS24460UC, WAS20160UC, WAE20060UC.
Leveling the dryer
Importance of leveling the dryer
It is important that your dryer is level and that all four
dryer feet press with equal pressure against the floor.
This will help assure the quietest, most vibration-free use
of your dryer.