GAS CONNECTION
   
To avoid gas leaks, the pressure test-point stopper
valve and gasket supplied with the range must be
installed on the gas fitting at the back of the range
according to the diagram below.
M  
All gas connections must comply with national
and local codes. The gas supply line (service)
must be the same size or greater than the inlet
line of the appliance. This range uses a 1/2"
NPT inlet (see drawing below for details of gas
connection). On all pipe joints use appropriate
sealant resistant to gas.
This range can be used with Natural or
LP/Propane gas. The range is shipped from the
factory for use with natural gas.
For LP/propane household installation, the
appliance must be converted by the dealer, by a
factory-trained professional or by a qualified
licensed plumber or gas service company.
Gas conversion is important for safe and
effective use of the appliance. It is the
responsibility of the dealer and the owner of the
range to perform the appropriate gas
conversion following the directions of the
manufacturer.
THE GAS CONVERSION PROCEDURE IS
DESCRIBED IN THIS MANUAL AND IN
THE PACKAGE CONTAINING THE
CONVERSION NOZZLES SHIPPED WITH
EVERY RANGE.
Please provide the service person with this
manual before work is started on the range.
WARNING!
DO NOT USE AN OPEN FLAME WHEN
CHECKING FOR LEAKS!
THIS VALVE IS NOT SHIPPED WITH
THE APPLIANCE AND MUST BE
SUPPLIED BY THE INSTALLER.
The manual shut-off valve must be installed
in the gas service line between the gas
hook-up on the wall and the appliance inlet,
in a position where it can be reached quickly
in the event of an emergency.
In Massachusetts: A T handle type manual
gas valve must be installed in the gas
supply line to this appliance.
 
In case of installation with flexible couplings
and/or quick-disconnect fittings, the installer
must use a heavy-duty, AGA
design-certified commercial flexible
connector of at least 1/2" (1.3 cm) ID NPT
(with suitable strain reliefs) in compliance
with ANSI Z21.41 and Z21.69 standards.
In Massachusetts: The unit must be
installed with a 36" (3-foot) long flexible gas
connector.
In Canada: use CAN 1-6.10-88 metal
connectors for gas appliances and CAN
1-6.9 M79 quick disconnect device for use
with gas fuel.
Leak testing of the appliance shall be
conducted according to the manufacturer's
instructions. Before placing the oven into
operation, always check for leaks with soapy
water solution or other acceptable method.
Check for gas leakage with soapy water
solution or other acceptable methods in all gas
connections installed between inlet gas pipe of
the appliance, gas regulator, till to the manual
shut-off valve.