9
INSTALLATION REQUIREMENTS

A properly grounded and horizontally-mounted
electrical receptacle Type NEMA 14-50R should
be installed no higher than 3" (7.6 cm) above
the floor, no less than 2" (5 cm) and no more
than 8" (20,3 cm) from the left side (facing
product); refer to ELECTRICAL CONNECTION
section pag. 13.
INTLLTION ENT TO
ITHEN INET
This range may be installed directly
adjacent to existing countertop high
cabinets (36" or 91.5 cm from the floor).
For the best look, the worktop should be level with
the cabinet countertop. This can be accomplished
by raising the unit using the adjustment spindles
on the legs.
e ll lol ode eee

An agency-approved, properly-sized manual
shut-off valve should be installed no higher than 3"
(7.6 cm) above the floor and no less than 2" (5 cm)
and no more than 8" (20.3 cm) from the right side
(facing product).
To connect gas between shut-off valve and
regulator, use agency-approved, properly sized
flexible or rigid pipe. Check all local code
requirements.
ATTENTION: the range CANNOT be installed
directly adjacent to kitchen walls, tall cabinets, tall
appliances, or other vertical surfaces above 36"
(91.4 cm) high. The minimum side clearance in
such cases is 6" (15.2 cm).
Wall cabinets with minimum side clearance must
be installed 30" above the countertop
with countertop height between 35 " (90.2 cm)
and 37 " (94.6 cm). The maximum depth of wall
cabinets above the range shall be 13" (33.0 cm)
OPENING WIDTH
COOKING RANGE
W
30"Model
30"(757)
36"Model
36"(910)
48"Model
48"(1215)
60"Model
60"(1520)
RANGE
3 23"
(82)
FRONT VIEW
30"
(762)
6"
(152)
(65)
(930)
T
O
COOKING
SURFACE
W
OPENING WIDTH
30"
(762)
TO
36"
(914)
TO BOTTOM OF
VENTILATION HOOD
*
E
LOCATION OF GAS AND
ELECTRICAL EXTENDS
ON FLOOR
SIDE VIEW
.
13"
(330)
3 15"
(80)
.
12"
(305) GAS
5"
(127)
2"
(51)
G
5
3
/
4
"
(146)
(250)
9
3
/
4
"
36
3
/
5
"
2
3
/5"
1
/
2
1
/
4