8
UNIVERSAL LPG AND PROPANE INSTALLATION
UNIVERSAL LPG AND PROPANE INSTALLATION
NOTE: Conversion of this unit to LPG or Propane must be
carried out by a qualified licensed person and a Certificate
of Compliance must be issued to the owner on completion of
the installation and conversion�
Converting the unit to LPG or Propane gas
This barbecue is set up for Natural gas and is labelled
accordingly� A LPG and Propane conversion Kit is supplied
with the product�
The components in the kit are:
• Brass adaptor
• Sealing washer
• Small plastic bag containing:
– 6 x 0�9 brass injectors (Universal LPG)
• Small plastic bag containing:
– 6 x 0�95 brass injectors (Propane)
• LPG sticker
• Propane sticker
1. Replace ‘gas type’ sticker
• Locate ‘Natural gas’ sticker located on the barbecue
gas inlet and remove it� Put either the LPG or propane
sticker in it’s place�
2. Change the injectors
• Remove the clip that retains the spark electrode to the
burner�
• Release the burner from the retaining bracket by lifting
as shown�
• Unscrew Natural gas injectors and replace with
either Universal LPG or Propane injectors�
Universal LPG injectors have 0�90mm diameter
orifice� Propane Gas injectors have 0�95mm diameter
orifice� All injectors are marked with the orifice size�
• Install burner and spark electrode with retaining clip
• Repeat for the other 5 burners
NOTE: The final step in the conversion of the barbecue to
either Universal LPG or Propane is the adjustment of the
turndown setting�
This can only be completed after the barbecue has been
connected to a supply of gas� Refer to ‘Connection to Universal
LPG and Propane Gas Supply’ detailed in next section�
3. Adjust the turndown setting on the valve
• Light each burner and rotate the control knob to the
lowest setting, then remove the knob from the valve
shaft, and remove the grommet�
• Using a small flat-blade screwdriver adjust the
turndown adjustment screw to achieve a small steady
flame on the burner�
Turndown screw
• Replace the grommet and the knob
• Recheck the operation of the burner at maximum and
turndown
• Repeat procedures for all valves�
Remove 1�75mm injector
and install 0�90mm injector
for LPG gas or 0�95mm for
Propane gas�
Remove burner to
access injector