8
UNIVERSAL LPG AND PROPANE INSTALLATION
UNIVERSAL LPG AND PROPANE INSTALLATION
NOTE: Conversion of this unit to LPG or Propane must be
carried out by a qualified licensed person and a Certificate
of Compliance must be issued to the owner on completion of
the installation and conversion�
Converting the unit to LPG or Propane gas
This barbecue is set up for Natural gas and is labelled
accordingly� A LPG and Propane conversion Kit is supplied
with the product�
The components in the kit are:
Brass adaptor
Sealing washer
Small plastic bag containing:
– 6 x 0�9 brass injectors (Universal LPG)
Small plastic bag containing:
– 6 x 0�95 brass injectors (Propane)
LPG sticker
Propane sticker
1. Replace ‘gas type’ sticker
Locate ‘Natural gas’ sticker located on the barbecue
gas inlet and remove it� Put either the LPG or propane
sticker in it’s place�
2. Change the injectors
Remove the clip that retains the spark electrode to the
burner
Release the burner from the retaining bracket by lifting
as shown�
Unscrew Natural gas injectors and replace with
either Universal LPG or Propane injectors�
Universal LPG injectors have 0�90mm diameter
orifice� Propane Gas injectors have 0�95mm diameter
orifice� All injectors are marked with the orifice size�
Install burner and spark electrode with retaining clip
Repeat for the other 5 burners
NOTE: The final step in the conversion of the barbecue to
either Universal LPG or Propane is the adjustment of the
turndown setting�
This can only be completed after the barbecue has been
connected to a supply of gas� Refer to ‘Connection to Universal
LPG and Propane Gas Supply’ detailed in next section�
3. Adjust the turndown setting on the valve
Light each burner and rotate the control knob to the
lowest setting, then remove the knob from the valve
shaft, and remove the grommet�
Using a small flat-blade screwdriver adjust the
turndown adjustment screw to achieve a small steady
flame on the burner
Turndown screw
Replace the grommet and the knob
Recheck the operation of the burner at maximum and
turndown
Repeat procedures for all valves�
Remove 1�75mm injector
and install 0�90mm injector
for LPG gas or 0�95mm for
Propane gas�
Remove burner to
access injector
Loading ...