At least twice each year, lower motor housing (A) to check motor assembly (D), and then tighten all
screws on fan. Clean motor housing (A) with only a soft brush (not included) or lint-free cloth (not
included) to avoid scratching the finish. Clean blades (H) with a lint-free cloth. You may occasionally
apply a light coat of furniture polish (not included) to wood blades for added protection.
Important: Shut off main power supply before beginning any maintenance. Do not use water or a
damp cloth to clean the ceiling fan.
CARE AND MAINTENANCE
TROUBLESHOOTING
If you have any questions regarding the product please call customer service at 1-800-527-1292,
8:30 a.m. - 5 p.m., CST, Monday - Friday.
Warning: Before beginning work, shut off the power supply to avoid electrical shock.
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Fan does not move.
1. Reverse switch not engaged.
2. Power is off or fuse is blown.
3. Faulty wire connection.
4. Wires not connected properly.
1. Push switch firmly either to the
right or to the left.
2. Turn power on or check fuse.
3. Turn power off. Loosen motor
housing (A) and check all
connections.
4. Check that molex connections in
light kit fitter (E) are connected
properly according to
instructions on page 12.
Noisy operation. 1. Blades (H) are loose.
2. Cracked blade (H).
3. Full range dimmer switch.
4. Fan is new.
5. Motor housing (A) is loose.
1. Tighten all blade screws (AA).
2. Replace blade (H).
3. Replace with an approved
speed control device.
4. Allow fan a “break in” period of a
few days, especially when
running the fan at Medium and
High speeds.
5. Turn power off. Carefully loosen
motor housing (A) and verify
that mounting bracket (B) is
secure according to instructions
on page 11.
Excessive wobbling.
1. Blades (H) are loose.
2. Blade arms (G) incorrectly attached.
3. Unbalanced blades (H).
4. Fan not securely mounted.
1. Tighten all blade screws (AA).
2. Re-install blade arms (G).
3. Switch one blade (H) with a
blade (H) from the opposite
side.
4. Turn power off. Carefully loosen
motor housing (A) and verify
that mounting bracket (B) is
secure.