Installation
FREESTANDING INSTALLATION
A freestanding installation will allow you to install the beverage refrigerator in any place you desire provided
that the required clearance space around the appliance is respected. In every setting, there must be an ad-
equate ventilation and access for service. Never install or operate the unit in an enclosed area, such as a
closed cabinet. Allowance of at least 5 inches (127mm) of space between the back and sides of the appli-
ance are suggested, which allows the proper air circulation to cool the compressor and condenser.
ELECTRICAL CONNECTION
WARNING: Improper use of the grounded plug can result in the risk of electrical shock. If the power
cord is damaged, have it replaced by a qualified electrician or contact Whynter Service Department.
This appliance requires a standard 115/120 Volt AC ~/60Hz electrical ground outlet with three-prong.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly
grounded. The cord should be secured behind the appliance and not left exposed or dangling to prevent
accidental injury.
The appliance should always be plugged into its own individual electrical outlet which has a voltage rat-
ing that matches the rating label on the appliance. This provides the best performance and also prevent
overloading house wiring circuits that could cause a fire hazard from overheated. Never unplug the ap-
pliance by pulling the power cord. Always grip the plug firmly and pull straight out from the receptacle.
Repair or replace immediately all power cords that have become frayed or otherwise damaged. Do not
use a cord that shows cracks or abrasion damage along its length or at either end. When moving the
appliance, be careful not to damage the power cord.
EXTENSION CORD
Because of potential safety hazards, it is strongly recommended that you do not use an extension cord
with this appliance. However, if you must use an extension cord, it is absolutely necessary that it be a
UL/CUL-Listed, 3-wire grounding type appliance extension cord having a grounding type plug and outlet
and that the electrical rating of the cord be 115 volts and at least 10 amperes.