9
4. Gas supply pipe must be located within the shaded area as
shown in the “Cabinet Dimensions” illustration in “Location
Requirements” section.
Complete connection
1. Open the manual shut-off valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
3. Remove cooktop burner caps and grates from parts
package. Align recess in burner caps with pins in burner
base. Burner caps should be level when properly positioned.
If burner caps are not properly positioned, surface burners
will not light. Place burner grates over burners and caps.
4. Plug into a grounded 3 prong outlet.
Verify Anti-Tip Bracket Is Installed and
Engaged
1. Place the outside of your foot against the bottom front of
the oven door to keep the range from moving, and grasp the
lower right or left side of the control panel as shown.
NOTE: If your countertop is mounted with a backsplash, it
may be necessary to grasp the range higher than is shown in
the illustration.
2. Slowly attempt to tilt the range forward.
If you encounter immediate resistance, the range foot is
engaged in the anti-tip bracket.
3. If the rear of the range lifts more than
1
/
2
" (1.3 cm) off the
floor without resistance, stop tilting the range and lower it
gently back to the floor. The range foot is not engaged in the
anti-tip bracket.
IMPORTANT: If there is a snapping or popping sound when
lifting the range, the range may not be fully engaged in the
bracket. Check to see if there are obstructions keeping the range
from sliding to the wall or keeping the range foot from sliding
into the bracket. Verify that the bracket is held securely in place
by the mounting screws.
4. Slide the range forward and verify that the anti-tip bracket is
securely attached to the floor or wall.
5. Slide range back so the rear range foot is inserted into the
slot of the anti-tip bracket.
IMPORTANT: If the back of the range is more than 2" (5.1 cm)
from the mounting wall, the rear range foot may not engage
the bracket. Slide the range forward and determine if there
is an obstruction between the range and the mounting wall.
If you need assistance or service, refer to the “Assistance or
Service” section of the Use and Care Guide, or the cover or
the “Warranty” section of the User Instructions, for contact
information.
6. Repeat steps 1 and 2 to ensure that the range foot is
engaged in the anti-tip bracket.
If the rear of the range lifts more than
1
/
2
" (1.3 cm) off
the floor without resistance, the anti-tip bracket may not
be installed correctly. Do not operate the range without
anti-tip bracket installed and engaged. Please reference
the “Assistance or Service” section of the Use and Care
Guide, or the cover or the “Warranty” section of the User
Instructions, to contact service.
Adaptor
A
B
C
D
A. Gas pressure regulator
B. Adapter
C. Flexible connector
D. Manual shut-off valve
A
B
A. Closed valve
B. Open valve
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING