Sq.Ft. Continuus Washers & Dryers

User Manual - Page 19

For Sq.Ft..

PDF File Manual, 22 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
15
Malfunction Codes
● Unit's Malfunction Codes
Display
Code
Display
Window
Ambient temperature sensor is
loosen or is poorly connected
with the terminal of display board.
Some element of display board
may have been put upside down
and cause short circuit.
Ambient temperature sensor is
damaged(Please refer to Checking
Table for Temperature Sensor
Resistance).
Display board is damaged.
Temperature sensor on the
evaporator is loosen or is poorly
connected with the terminal of
display board.
Some element of display board
may have been put upside down
and cause short circuit.
Temperature sensor on the evaporator
is damaged(Please refer
to Checking Table for Temperature
Sensor Resistance).
Display board is damaged.
Temperature sensor on the
evaporator is loosen or is poorly
connected with the terminal of
display board.
Some element of display board
may have been put upside down
and cause short circuit.
Discharge temperature sensor is
damaged (Please refer
to Checking Table for Temperature
Sensor Resistance).
Display board is damaged.
Humidity sensor is short-circuited.
Humidity sensor is damaged.
Display board is damaged.
2
3
4
Compressor
and fan
motor stop.
The buttons
are invalid.
F2
Tube
Temperature
Sensor
Malfunction
L1
Humidity
Sensor
Malfunction
Discharge
Temperature
Sensor
Malfunction
F5
No.
Malfunction
Name
Unit's
Condition
Possible Causes
F1
Ambient
Temperature
Sensor
Malfunction
1
Loading ...
Loading ...
Loading ...