9.3 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Rapid 52
Semi-rapid 32
9.4 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 4,8 kW
Gas replacement: G30 (3+) 28-30 mbar = 334 g/h
G31 (3+) 37 mbar = 329 g/h
Electric zones: 3,7 kW
Electric supply: 220-240 V ~ 50-60 Hz
Appliance category: II2H3+
Gas connection: R 1/2"
Appliance class: 3
9.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
Rapid 2,9 0,75 119
Semi-rapid 1,9 0,45 96
9.6 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Rapid 2,7 0,75 86 196 193
Semi-rapid 1,9 0,45 71 138 136
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification HD634170NB
Type of hob Built-in hob
Number of electric cooking zones 2
ENGLISH 25