User Manual Danby DDR050BGWDB 50 Pint Dehumidifier

Danby DDR050BGWDB 50 Pint Dehumidifier - Use Manual - Use Guide PDF.
Documents: Go to download!
  • Owner's manual - (English, French, Spanish)



OWNER’S MANUAL Dehumidifier

OPERATING INSTRUCTIONS

LOCATION

  • Place the dehumidifi er on a smooth, level fl oor that is strong enough to support the appliance with a full bucket of water.
  • To maintain effi ciency, operate the appliance in an enclosed area. Keep nearby doors and windows closed.
  • Maintain a minimum clearance of 20 cm (8 inches) on the sides and back of the appliance and 40 cm (16 inches) on the top of the appliance to allow for proper air circulation.
  • The recommended ambient operating temperature is between 5°C (41°F) and 35°C (95°F).
  • Do not force rollers to move over carpeting as the appliance may tip over and spill water.
  • Any time the appliance is placed on its back or side, it must be allowed to stand upright for 6 hours before plugging in to avoid damage to internal components.

FEATURES

Front

Back

CONTROL PANEL

  1. Defrost Indicator Light
    • The defrost indicator light will illuminate when frost has accumulated on the interior of the appliance. This can indicate that the ambient temperature is too cold. The dehumidifying function will cease until the frost has melted.
  2. Full Bucket Indicator Light
    • The full bucket indicator light will illuminate when the bucket is full of water. Empty the bucket to resume regular functioning.
  3. Display
    • The display will show the set humidity, the ambient humidity or the timer function.
    • The humidity can be set between 35-85% in 5% increments. For drier air, set the humidity to a lower number. For damper air, set the humidity to a higher number.
    • The ambient humidity display is accurate within +/- 5%.
  4. Smart Dehumidify Button and Indicator Light
    • Use this button to activate smart dehumidify mode. Smart dehumidify mode will automatically set the humidity and fan speed based on the ambient temperature and humidity. The indicator light will illuminate when smart dehumidify is active.
  5. Filter Button and Indicator Light
    • The fi lter light will illuminate when the filter needs to be cleaned. Press the fi lter button once the filter has been cleaned to return to regular functioning.
  6. Continuous Mode Button and Indicator Light
    • Press this button to activate continuous mode. This will run the dehumidifying function continuously. The indicator light will turn on when continuous mode is active.
  7. Fan Button and Indicator Light
    • Press this button to set the fan speed to low or high. If the indicator light is off, the fan is set to low speed. If the indicator light is on, the fan is set to high speed.
  8. Timer Button and Indicator Lights
    • Use this button to set the timer function.
  9. Up and Down Arrows
    • The up and down arrows can adjust the set humidity or the timer setting.
  10. Power Button
    • Use this button to turn the appliance on or off.

TIMER FUNCTION

Auto On Function

  1. Press the timer button until the auto on indicator light illuminates.
  2. Use the up and down arrows to select the desired amount of time before the appliance should turn on. The up and down arrows will add or subtract 30 minutes of time up to 10 hours, then at 1 hour increments up to a maximum of 24 hours.
  3. The time selected will appear on the display panel and will count down until the appliance turns on.

Auto Off Function

  1. Press the timer button until the auto-off indicator light illuminates.
  2. Use the up and down arrows to select the desired amount of time before the appliance should turn on. The up and down arrows will add or subtract 30 minutes of time up to 10 hours, then at 1 hour increments up to a maximum of 24 hours.
  3. The time selected will appear on the display panel and will count down until the appliance turns off.

Using Auto On and Auto Off Simultaneously

  • The auto on and auto off functions can be used at the same time by first setting one and then the other. Both indicator lights will illuminate and the display will count down to the appliance either turning off or on, whichever function was set first.
  • Note: The timer will not cycle the appliance on and off indefinitely. The auto on and auto off timers will function one time and then the appliance will return to regular functioning.
  • Turning the appliance off, pressing the default button on the remote or unplugging the appliance will clear all memory settings, including the timer

WATER REMOVAL

There are two ways to remove collected water from the appliance.

1. Water Bucket

  • The dehumidifier will automatically collect condensed water in the water bucket. When the bucket is full, the compressor and fan will turn off and the full bucket indicator light will turn on. The display will show “P2”.
  • To empty the bucket, gently remove it from the appliance by gripping both sides and pulling outward. Be cautious when removing the bucket, it will be full and can be heavy.
  • Do not place the water bucket directly on the floor. The bottom of the bucket is uneven and it will fall over and spill water.
  • Empty the bucket and replace it in the appliance. The dehumidifier will not function without the bucket installed.

2. Continuous Drain

  • Water can be removed from the appliance using the continuous drain and a standard garden hose (not provided).
  • Remove the cover from the continuous drain outlet and attach the female threaded end of the garden hose to the back of the appliance. Direct the other end of the garden hose to a bucket or floor drain.
  • Ensure that the garden hose is not bent and goes straight down from the back of the appliance. The continuous drain is only activated by gravity so any bends or upward motion in the hose will stop the water from draining.
  • The garden hose should be cut so that it is no more than 1.8 m (6 feet) long. If the drain hose is too long water may not drain completely which can lead to stagnant water and mildew build up inside the hose.

CARE & MAINTENANCE

AIR FILTER

The air filter should be cleaned approximately every 2 weeks. The air filter may require more frequent cleaning if there is significant dander or fur in the air.

Approximately every two weeks, the fi lter indicator light on the control panel will illuminate as a reminder to clean the fi lter. Follow the steps below to clean the filter and return the appliance to normal functioning.

  1. The air filter is located behind the rear intake grill. To remove the air filter, grasp the filter tab on the bottom of the grill and slide it downward.
  2. Use a vacuum cleaner with a soft brush attachment to remove any large debris or dust build up from the air filter.
  3. Wash the filter in lukewarm, soapy water, below 40°C (104°F), or use a neutral cleaning agent.
  4. Rinse the filter with clean water and dry thoroughly before reinstalling in the appliance.
  5. Press the filter button on the control panel to resume normal functioning. Note: Do not operate the appliance without the air fi lter installed.

ERROR CODES

If the display panel shows any of the below error codes, unplug the appliance, let it stand for 5-10 minutes and then plug it back in. If the error persists, call for service.

  • AS - Humidity sensor error
  • ES - Temperature sensor error
  • P2 - Full bucket or bucket not in the correct position
  • EC - Cooling sensor error or sensor error

CLEANING

  • To avoid possible electric shock, ensure that the appliance is unplugged before performing any cleaning or maintenance.
  • The outside of the appliance can be wiped clean with a soft cloth or with a lukewarm, damp cloth if necessary.
  • Do not use gasoline, benzene, thinner or any other chemicals to clean this appliance as these substances can cause damage to the finish and deformation of plastic parts.
  • Never pour water directly onto the appliance as this will cause deterioration of electrical components and wiring insulation.

END OF SEASON CARE

  • Before removing the appliance from service for the year, operate the appliance on high fan mode for half a day to ensure that the inside of the appliance is dry. This will help avoid the growth of mold or mildew inside the appliance. Ensure the filter is clean and dry. Store the appliance covered in a dry location.

DISPOSAL

  • This appliance may not be treated as regular household waste, it should be taken to the appropriate waste collection point for recycling of electrical components. Check for local regulatory compliance regarding approved and safe disposal of this appliance.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE
Appliance will not operate

Plug is not fully inserted into the wall outlet

Blown fuse or circuit breaker

Ambient humidity is lower than the set humidity

Bucket is full or is not in the proper position

Insufficient dehumidifying

Airfi lter is dirty

Blocked air flow

Appliance size is too small for application

Ambient humidity is lower than the set humidity

Noise

Air filter is dirty

Bucket is not in proper position

Floor surface is not level

Odors

Formation of mold or mildew on internal wet surfaces

Place an algaecide tablet in the water bucket

Water on floor

Hose connection is loose

Drain cover has been removed

Frost build up

When ambient temperature is below 5°C (41°F) frost may form

Switch the appliance to fan only mode until the frost melts



See other models: DDR050BDWDB DDR045BDWDB DDR030EAWDB DDR030BHWDB DDR030BDWDB

Danby DDR050BGWDB | File type: PDF | Filename: Danby 50 Pint Dehumidifier DDR050BGWDB.pdf | Size: 1.05 MB | Language: English, French, Spanish

Download User Manual

Product Infomation and Reviews - DDR050BGWDB photo

DDR050BGWDB Photo

Danby in United States

1-800-263-2629

Danby DDR050BGWDB Questions and Answers

Find answers or Ask a question.
  • Total questions: 2
  • Questions unAnswered : 2

Q: Unit is not pumping. What could be wrong. It was pumping. but stopped Reply

Q: Why is the pump not working? the unit is brand new! Reply