Burner and nozzle characteristics tables
1 Natural gas G20 AUX SR R UR-3c
Rated heating capacity (kW) 1.05 1.8 3.0 3.5
Nozzle diameter (1/100 mm) 72 97 115 134
Pre-chamber (printed on nozzle) (X) (Z) (Y) (F3)
Reduced flow rate (W) 400 500 800 1600
2 Natural gas G20 AUX SR R UR-3c
Rated heating capacity (kW) 1.05 1.8 3.0 3.5
Nozzle diameter (1/100 mm) 72 94 113 128
Pre-chamber (printed on nozzle) (X) (Z) (H8) (S)
Reduced flow rate (W) 400 500 800 1600
3 Natural gas G25 AUX SR R UR-3c
Rated heating capacity (kW) 1.05 1.8 3.0 3.5
Nozzle diameter (1/100 mm) 72 94 121 138
Pre-chamber (printed on nozzle) (F1) (Y) (F2) (F3)
Reduced flow rate (W) 400 500 800 1600
4 Natural gas G25.1 AUX SR R UR-3c
Rated heating capacity (kW) 1.05 1.8 3.0 3.5
Nozzle diameter (1/100 mm) 77 100 134 145
Pre-chamber (printed on nozzle) (F1) (Y) (F3) (F3)
Reduced flow rate (W) 400 500 800 1600
5 Natural gas G25 AUX SR R UR-3c
Rated heating capacity (kW) 1.05 1.8 3.0 3.5
Nozzle diameter (1/100 mm) 77 100 134 145
Pre-chamber (printed on nozzle) (F1) (Y) (F3) (F3)
Reduced flow rate (W) 400 500 800 1600
6 Natural gas G27 AUX SR R UR-3c
Rated heating capacity (kW) 1.05 1.8 3.0 3.5
Nozzle diameter (1/100 mm) 77 105 138 152
Pre-chamber (printed on nozzle) (F1) (Y) (F3) (F3)
Reduced flow rate (W) 400 500 800 1600
7 Natural gas G2.350 AUX SR R UR-3c
Rated heating capacity (kW) 1.0 1.8 3.0 3.6
Nozzle diameter (1/100 mm) 94 120 165 200
Pre-chamber (printed on nozzle) (Y) (Y) (F3) (H3)
Reduced flow rate (W) 400 500 800 1600