13
installed these rear wheels will keep the unit from moving if you step on the
foot brakes (See Figure 2):
2. Install the coffee tower assembly and the mixed ball valve:
a) Plug the coffee tower assembly into the top cover of the coffee dispenser:
3.0” tower: This does not require a tower
buckle. Put coffee tower directly over the
hole at the top of the coffee dispenser’s
upper surface. Fix the tower assembly
with screws directly on the upper surface
of the coffee dispenser. (See Fig. 3).
2.5” tower: This requires the tower buckle.
Place the coffee tower at the hole in the upper surface of the coffee
dispenser at an inclination of 60, and rotate 60 clockwise along the card
slot. Be sure the tap is facing toward the front of the machine. Attach the
coffee tower with washers (See Figure 4).
b) Take out the accessories of the mixed ball valve. Attach the transparent
hose to the coffee outlet of the mixed ball valve (See Figure 5).
3. Install N
2
gas cylinder and N
2
regulator valve:
a) Fix the two N
2
hose clamps on the
N
2
tube (See Figure 6).
b) Connect the ends of the N
2
tube
respectively to the N
2
intake port of the
mixed ball valve and the round outlet of
the N
2
regulator valve. Lock these
connections firmly with the two clamps on
the N
2
tube (See Figure 7).
c) Using the wrench, tighten the N
2
regulator table valve with the hex nut port
to the gas outlet of the N
2
tank (See Figure 8).
N
2
regulator
valve
Safety switch
N
2
tube
Bracket and retainer
of N
2
tank
Regulating
table
N
2
gas
cylinder
Loading ...