Position
Niche size
W D H
A 562 x 550 x 450
B 562 x 500 x 450
Installation
A
B
The microwave can be fitted in position A or B:
Installing the appliance
1. Remove all packaging and check
carefully for any signs of damage.
2. Fit the fixing hooks to the kitchen
cupboard using the instruction sheet and
template supplied.
3. Fit the appliance into the kitchen
cupboard slowly, and without force. The
appliance should be lifted onto the fixing
hooks and then lowered into place. In the
case of interference during fitting, this
hook is reversible. The front frame of the
oven should seal against the front
opening of the cupboard.
4. Ensure the appliance is stable and not
leaning. Ensure that a 4 mm gap is kept
between the cupboard door above and
the top of the frame (see diagram).
Measurements in (mm)
IMPORTANT! Ensure the bottom of
the oven is 85 cm or more above the
floor. It is important to ensure that the
installation of this product conforms to
the instructions in this operation
manual and the conventional oven
manufacturer’s installation instructions.