
Beforeusingyourairconditioner,pleaseread
thismanualcarefullyandkeepitforfuturereference.
ROOMAIRCONDITIONER
ReadThisManual
Insideyouwillfindmanyhelpfulhintsonhow
touseandmaintainyourairconditionerproperly.
Justalittlepreventativecareonyourpartcan
saveyouagreatdealoftimeandmoneyover
thelifeofyourairconditioner.You'llfindmany
answerstocommonproblemsinthechartof
troubleshootingtips.Ifyoureviewthechartof
TroubleshootingTipsfirst,youmaynotneed
tocallforservice.
Thedesignandspecificationsaresubjecttochangewithoutpriornoticefor
productimprovement.Consultwiththesalesagencyormanufacturerfordetails.
SPLITTYPE-
CS503U-C8
202000192036
20110618
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

CONTENTS
SOCIABLEREMARK
DISPOSAL: Donotdisposethisproductasunsortedmunicipalwaste.Collection
ofsuchwasteseparatelyforspecialtreatmentisnecessary.
Itisprohibitedtodisposeofthisapplianceindomestichouseholdwaste.
Fordisposal,thereareseveralpossibilities:
A)Themunicipalityhasestablishedcollectionsystems,whereelectronicwastecan
bedisposedofatleastfreeofchargetotheuser.
B)Whenbuyinganewproduct,theretailerwilltakebacktheoldproductatleast
freeofcharge.
C)Themanufacturewilltakebacktheoldappliancefordisposalatleastfreeof
chargetotheuser.
D)Asoldproductscontainvaluableresources,theycanbesoldtoscrapmetal
dealers.
Wilddisposalofwasteinforestsandlandscapesendangersyourhealthwhen
hazardoussubstancesleakintotheground-waterandfindtheirwayintothefood
chain.
WhenusingthisairconditionerintheEuropeancountries,thefollowing
informationsmustbefollowed:
SOCIABLEREMARK
SAFETYPRECAUTIONS
OPERATINGINSTRUCTIONS
CAREANDMAINTENANCE
OPERATIONTIPS
TROUBLESHOOTINGTIPS
Sociableremark.......................................................................................................................2
Warning..................................................................................................................................3
Caution...................................................................................................................................4
Partsnames..........................................................................................................................5
Indicatorlightsondisplaypanel................................................................................................6
Operatingtemperature.............................................................................................................7
Manualoperation....................................................................................................................7
Airflowdirectioncontrol..........................................................................................................8
Howtheairconditionerworks................................................................................................9
Careandmaintenance..........................................................................................................10
Operationtips......................................................................................................................12
Troubleshootingtips.............................................................................................................14
Contactanauthorisedservicetechnicianforrepairormaintenanceofthisunit.
Contacttheauthinstallerforinstallationofthisunit.
Youngchildrenshouldbesupervisedtoensurethattheydonotplaywiththe
airconditioner.
Ifthepowercordistobereplaced,replacementworkshallbeperformedby
authorisedpersonnelonly.
Installationworkmustbeperformedinaccordancewiththenationalwiring
standardsbyauthorisedpersonnelonly.
Thisapplianceisnotintendedforusebypersons(includingchildren)withreduced
physical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unless
theyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebya
personresponsiblefortheirsafety.
CAUTION
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

CONTENTS
SOCIABLEREMARK
DISPOSAL: Donotdisposethisproductasunsortedmunicipalwaste.Collection
ofsuchwasteseparatelyforspecialtreatmentisnecessary.
Itisprohibitedtodisposeofthisapplianceindomestichouseholdwaste.
Fordisposal,thereareseveralpossibilities:
A)Themunicipalityhasestablishedcollectionsystems,whereelectronicwastecan
bedisposedofatleastfreeofchargetotheuser.
B)Whenbuyinganewproduct,theretailerwilltakebacktheoldproductatleast
freeofcharge.
C)Themanufacturewilltakebacktheoldappliancefordisposalatleastfreeof
chargetotheuser.
D)Asoldproductscontainvaluableresources,theycanbesoldtoscrapmetal
dealers.
Wilddisposalofwasteinforestsandlandscapesendangersyourhealthwhen
hazardoussubstancesleakintotheground-waterandfindtheirwayintothefood
chain.
WhenusingthisairconditionerintheEuropeancountries,thefollowing
informationsmustbefollowed:
SOCIABLEREMARK
SAFETYPRECAUTIONS
OPERATINGINSTRUCTIONS
CAREANDMAINTENANCE
OPERATIONTIPS
TROUBLESHOOTINGTIPS
Sociableremark.......................................................................................................................2
Warning..................................................................................................................................3
Caution...................................................................................................................................4
Partsnames..........................................................................................................................5
Indicatorlightsondisplaypanel................................................................................................6
Operatingtemperature.............................................................................................................7
Manualoperation....................................................................................................................7
Airflowdirectioncontrol..........................................................................................................8
Howtheairconditionerworks................................................................................................9
Careandmaintenance..........................................................................................................10
Operationtips......................................................................................................................12
Troubleshootingtips.............................................................................................................14
Contactanauthorisedservicetechnicianforrepairormaintenanceofthisunit.
Contacttheauthinstallerforinstallationofthisunit.
Youngchildrenshouldbesupervisedtoensurethattheydonotplaywiththe
airconditioner.
Ifthepowercordistobereplaced,replacementworkshallbeperformedby
authorisedpersonnelonly.
Installationworkmustbeperformedinaccordancewiththenationalwiring
standardsbyauthorisedpersonnelonly.
Thisapplianceisnotintendedforusebypersons(includingchildren)withreduced
physical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unless
theyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebya
personresponsiblefortheirsafety.
CAUTION
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

SAFETYPRECAUTIONS
Topreventinjurytotheuserorotherpeopleandpropertydamage,thefollowinginstructions
mustbefollowed.Incorrectoperationduetoignoringofinstructionsmaycauseharmordamage.
Theseriousnessisclassifiedbythefollowingindications.
Thissymbolindicatesthepossibilityofdeathorseriousinjury.
Meaningsofsymbolsusedinthismanualareasshownbelow.
WARNING
Alwaysdothis.
Neverdothis.
CAUTION
Thissymbolindicatesthepossibilityofinjuryordamagetoproperty.
Connectwiththepower
properly.
Donotmodifypowercord
lengthorsharetheoutlet
withotherappliances
Alwaysensureeffective
earthing.
Disconnectthepowerif
strangesounds,smell,or
smokecomesfromit.
Ventilateroombeforeoperatingair
conditionerifthereisagasleakage
fromanotherappliance.
Otherwise,itmaycauseelectric
shockorfireduetoheat
generation.
excess
Itmaycauseelectricshock
orfireduetoheatgeneration.
Noearthingmaycause
electricshock.
Itmaycausefireand
electricshock.
Itmaycauseexplosion,fireand,burns.
Itmaycauseelectricshockorfire
duetoheatgeneration.
Itmaycauseelectricshock.
Itmaycausefailureof
machineorelectricshock.
Itcontainscontaminantsand
couldmakeyousick.
Itmaycausefireand
electricshock.
Itmaycauseelectricshock
orfire.
Thiscoulddamageyour
health.
Noinstallationmaycause
fireandelectricshock.
Itmaycauseelectricshock.
Itmaycauseanexplosionorfire.
Itmaycausefailureand
electricshock.
Donotoperateorstopthe
unitbyswitchingonoroff
thepower.
Donotoperatewithwet
handsorindamp
environment.
Donotallowwatertorun
intoelectricparts.
Donotdrinkwaterdrained
fromairconditioner.
Donotusethepowercord
closetoheatingappliances.
Donotdamageorusean
unspecifiedpowercord.
Donotdirectairflowat
roomoccupantsonly.
Alwaysinstallcircuit
breakerandadedicated
powercircuit.
Donotopentheunit
duringoperation.
Donotusethepowercordnear
flammablegasorcombustibles,such
asgasoline,benzene,thinner,etc.
Donotdisassembleor
modifyunit.
WARNING
Usethecorrectlyrated
breakerorfuse.
Thereisriskoffireor
electricshock.
SAFETYPRECAUTIONS
CAUTION
Whentheairfilteristobe
removed,donottouchthe
metalpartsoftheunit.
Itmaycauseaninjury.
Donotcleanunitwhen
powerisonasitmaycause
fireandelectricshock,itmay
causeaninjury.
Operationwithwindows
openedmaycausewetting
ofindoorandsoakingof
householdfurniture.
Whentheunitistobe
cleaned,switchoff,andturn
offthecircuitbreaker.
Stopoperationandclose
thewindowinstormor
hurricane.
Usecautionwhenunpacking
andinstalling.Sharpedges
couldcauseinjury.
Donotcleantheair
conditionerwithwater.
Watermayentertheunitand
degradetheinsulation.Itmay
causeanelectricshock.
Thiscouldinjurethepetor
plant.
Donotputapetorhouse
plantwhereitwillbe
exposedtodirectairflow.
Ventilatetheroomwell
whenusedtogether
withastove,etc.
Anoxygenshortage
mayoccur.
Donotusethisaircond-
itionertopreservepreci-
siondevices,food,pets,
plants,andartobjects.
Itmaycausedeterioration
ofquality,etc.
Itmaycausefailureof
productorfire.
Donotusefor
specialpurposes.
Turnoffthemainpower
switchwhennotsing
theunitforalongtime.
u
Ifwaterentersthe
unit,turntheunitoff
anddisconnectthe
power,contacta
qualifiedservice
technician.
Itmaycausefailureof
applianceoraccident.
Appearancemaybe
deterioratedduetochange
ofproductcoloror
scratchingofitssurface.
Donotplaceobstacles
aroundair-inletsorinside
ofair-outlet.
Donotusestrongdetergent
suchaswaxorthinner.Use
asoftclothforcleaning.
Ifbracketisdamaged,there
isconcernofdamagedueto
fallingofunit.
Thereisdangeroffireor
electricshock.
Ensurethattheinstallationbracketof
theoutdoorapplianceisnotdamaged
duetoprolongedexposure.
Donotplaceheavyobjectonthe
powercordandtakecaresothat
thecordisnotcompressed.
Operationwithoutfilters
maycausefailure.
Alwaysinsertthefilters
securely.Cleanfilter
onceeverytwoweeks.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

SAFETYPRECAUTIONS
Topreventinjurytotheuserorotherpeopleandpropertydamage,thefollowinginstructions
mustbefollowed.Incorrectoperationduetoignoringofinstructionsmaycauseharmordamage.
Theseriousnessisclassifiedbythefollowingindications.
Thissymbolindicatesthepossibilityofdeathorseriousinjury.
Meaningsofsymbolsusedinthismanualareasshownbelow.
WARNING
Alwaysdothis.
Neverdothis.
CAUTION
Thissymbolindicatesthepossibilityofinjuryordamagetoproperty.
Connectwiththepower
properly.
Donotmodifypowercord
lengthorsharetheoutlet
withotherappliances
Alwaysensureeffective
earthing.
Disconnectthepowerif
strangesounds,smell,or
smokecomesfromit.
Ventilateroombeforeoperatingair
conditionerifthereisagasleakage
fromanotherappliance.
Otherwise,itmaycauseelectric
shockorfireduetoheat
generation.
excess
Itmaycauseelectricshock
orfireduetoheatgeneration.
Noearthingmaycause
electricshock.
Itmaycausefireand
electricshock.
Itmaycauseexplosion,fireand,burns.
Itmaycauseelectricshockorfire
duetoheatgeneration.
Itmaycauseelectricshock.
Itmaycausefailureof
machineorelectricshock.
Itcontainscontaminantsand
couldmakeyousick.
Itmaycausefireand
electricshock.
Itmaycauseelectricshock
orfire.
Thiscoulddamageyour
health.
Noinstallationmaycause
fireandelectricshock.
Itmaycauseelectricshock.
Itmaycauseanexplosionorfire.
Itmaycausefailureand
electricshock.
Donotoperateorstopthe
unitbyswitchingonoroff
thepower.
Donotoperatewithwet
handsorindamp
environment.
Donotallowwatertorun
intoelectricparts.
Donotdrinkwaterdrained
fromairconditioner.
Donotusethepowercord
closetoheatingappliances.
Donotdamageorusean
unspecifiedpowercord.
Donotdirectairflowat
roomoccupantsonly.
Alwaysinstallcircuit
breakerandadedicated
powercircuit.
Donotopentheunit
duringoperation.
Donotusethepowercordnear
flammablegasorcombustibles,such
asgasoline,benzene,thinner,etc.
Donotdisassembleor
modifyunit.
WARNING
Usethecorrectlyrated
breakerorfuse.
Thereisriskoffireor
electricshock.
SAFETYPRECAUTIONS
CAUTION
Whentheairfilteristobe
removed,donottouchthe
metalpartsoftheunit.
Itmaycauseaninjury.
Donotcleanunitwhen
powerisonasitmaycause
fireandelectricshock,itmay
causeaninjury.
Operationwithwindows
openedmaycausewetting
ofindoorandsoakingof
householdfurniture.
Whentheunitistobe
cleaned,switchoff,andturn
offthecircuitbreaker.
Stopoperationandclose
thewindowinstormor
hurricane.
Usecautionwhenunpacking
andinstalling.Sharpedges
couldcauseinjury.
Donotcleantheair
conditionerwithwater.
Watermayentertheunitand
degradetheinsulation.Itmay
causeanelectricshock.
Thiscouldinjurethepetor
plant.
Donotputapetorhouse
plantwhereitwillbe
exposedtodirectairflow.
Ventilatetheroomwell
whenusedtogether
withastove,etc.
Anoxygenshortage
mayoccur.
Donotusethisaircond-
itionertopreservepreci-
siondevices,food,pets,
plants,andartobjects.
Itmaycausedeterioration
ofquality,etc.
Itmaycausefailureof
productorfire.
Donotusefor
specialpurposes.
Turnoffthemainpower
switchwhennotsing
theunitforalongtime.
u
Ifwaterentersthe
unit,turntheunitoff
anddisconnectthe
power,contacta
qualifiedservice
technician.
Itmaycausefailureof
applianceoraccident.
Appearancemaybe
deterioratedduetochange
ofproductcoloror
scratchingofitssurface.
Donotplaceobstacles
aroundair-inletsorinside
ofair-outlet.
Donotusestrongdetergent
suchaswaxorthinner.Use
asoftclothforcleaning.
Ifbracketisdamaged,there
isconcernofdamagedueto
fallingofunit.
Thereisdangeroffireor
electricshock.
Ensurethattheinstallationbracketof
theoutdoorapplianceisnotdamaged
duetoprolongedexposure.
Donotplaceheavyobjectonthe
powercordandtakecaresothat
thecordisnotcompressed.
Operationwithoutfilters
maycausefailure.
Alwaysinsertthefilters
securely.Cleanfilter
onceeverytwoweeks.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

OPERATINGINSTRUCTIONS OPERATINGINSTRUCTIONS
Partsnames
Indoorunit
3
2
4
1
6
7
5
8.Connectivecable
9.Connectivepipe
10.Stopvalve
Outdoorunit
NOTE: Theindoorunityoupurchasedwouldlikeoneofthefollowing.Thereisaslightly
differenceonfrontpanelanddisplaywindow,butthefeaturesarethesame.
NOTE:
Allthepicturesinthismanualarefor
explanationpurposeonly.Yourair
conditionermaybeslightlydifferent.
Theactualshapeshallprevail.
Airinlet
Airoutlet
8
9
10
Outdoorunit
Airinlet(rear)
Airinlet(side)
Airoutlet
1.Frontpanel
2.Airinlet
3.
4.
5.Displaypanel
6.Connectingpipe
7.Drainhose
Horizontalairflowgrille
Verticalairflowlouver
Indoorunit
(A)
(B)
IndicatorLightsonDisplaypanel
Thedisplaypanelontheindoorunit
wouldlooklikeoneofthefollowing:
AUTOindicator:
DEFROSTIndicator
DIGITALDISPLAY:
indicator:
TIMERindicator:
Thisindicatorilluminateswhen
theairconditionerisinAUTO
operation.
(Forcooling&heatingmodelonly):
Thisindicatorilluminateswhen
theairconditionerstartsdefrosting
automaticallyorwhenthewarm
aircontrolfeatureisactivatedin
heatingoperation.
Displaysthecurrentsetting
temperaturewhentheair
conditionerisinoperation.
Theindicatorflashesonceevery
secondafterpowerisonand
illuminateswhentheairconditioner
isinoperation.
Theindicatorilluminateswhen
TIMERissetON/OFF.
OPERATION
1
2
3
4
5
11 2 3
4 5
Signal
receptor
(1)
(2)
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

OPERATINGINSTRUCTIONS OPERATINGINSTRUCTIONS
Partsnames
Indoorunit
3
2
4
1
6
7
5
8.Connectivecable
9.Connectivepipe
10.Stopvalve
Outdoorunit
NOTE: Theindoorunityoupurchasedwouldlikeoneofthefollowing.Thereisaslightly
differenceonfrontpanelanddisplaywindow,butthefeaturesarethesame.
NOTE:
Allthepicturesinthismanualarefor
explanationpurposeonly.Yourair
conditionermaybeslightlydifferent.
Theactualshapeshallprevail.
Airinlet
Airoutlet
8
9
10
Outdoorunit
Airinlet(rear)
Airinlet(side)
Airoutlet
1.Frontpanel
2.Airinlet
3.
4.
5.Displaypanel
6.Connectingpipe
7.Drainhose
Horizontalairflowgrille
Verticalairflowlouver
Indoorunit
(A)
(B)
IndicatorLightsonDisplaypanel
Thedisplaypanelontheindoorunit
wouldlooklikeoneofthefollowing:
AUTOindicator:
DEFROSTIndicator
DIGITALDISPLAY:
indicator:
TIMERindicator:
Thisindicatorilluminateswhen
theairconditionerisinAUTO
operation.
(Forcooling&heatingmodelonly):
Thisindicatorilluminateswhen
theairconditionerstartsdefrosting
automaticallyorwhenthewarm
aircontrolfeatureisactivatedin
heatingoperation.
Displaysthecurrentsetting
temperaturewhentheair
conditionerisinoperation.
Theindicatorflashesonceevery
secondafterpowerisonand
illuminateswhentheairconditioner
isinoperation.
Theindicatorilluminateswhen
TIMERissetON/OFF.
OPERATION
1
2
3
4
5
11 2 3
4 5
Signal
receptor
(1)
(2)
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

OPERATINGINSTRUCTIONS
Airflowdirectioncontrol
Adjusttheairflowdirectionproperlyotherwise,it
mightcausediscomfortorcauseunevenroom
temperatures.
Adjustthehorizontallouverusingtheremote
controller.
Adjusttheverticallouvermanually.
Performthisfunctionwhiletheunitisinoperation.
Usetheremotecontrollertoadjusttheairflow
direction.Thehorizontallouvercanbemovedat
arangeof6foreachpress,orswingupanddown
automatically.PleaserefertotheREMOTE
CONTROLLEROPERATIONMANUALfordetails.
Tosettheverticalairflow(Up--Down)direction
O
Movetheverticallouvermanuallytoadjusttheairflow
inthedirectionyouprefer.
:Beforeadjustingtheverticallouvers,the
supplypowermustbedisconnected.
Forsomemodels,theverticallouvercanbeadjusted
byusingtheremotecontroller.Pleaserefertothe
REMOTECONTROLLEROPERATIONMANUAL
fordetails.
Tosetthehorizontalairflowdirection(left-right)
IMPORTANT
Donotoperatetheairconditionerforlongperiodswith
theairflowdirectionsetdownwardincoolingor
dehumidifyingmode.Otherwise,condensationmay
occuronthesurfaceofthehorizontallouvercausing
moisturetodropontothefloororonfurnishings.
Donotmovethehorizontallouvermanuallyunlessitis
necessary.Alwaysusetheremotecontroller.
Whentheairconditionerisstartedimmediatelyafterit
wasstopped,thehorizontallouvermightnotmovefor
approximately10seconds.
Openangleofthehorizontallouvershouldnotbeset
toosmall,asCOOLINGorHEATINGperformancemay
beimpairedduetotoorestrictedairflowarea.
Donotoperateunitwithhorizontallouverinclosed
position.
Whentheairconditionerisconnectedtopower(initial
power),thehorizontallouvermaygenerateasoundfor
10seconds,thisisanormaloperation.
CAUTION
,,
,,
,,
,,
Manuloperationcanbeusedtemporarilyincasetheremotecontrollerisdisableor
maintenancenecessary.
OPERATINGINSTRUCTIONS
Manualoperation
NOTE:ThismanualdoesnotincludeRemoteControllerOperations,seethe
<<RemoteControllerInstruction>>packedwiththeunitfordetails.
Operatingtemperature
Openandliftthefrontpaneluptoanangle
untilitremainsfixedwithaclickingsound.
PushthebuttonuntiltheAUTOindicator
islit,theunitwillworkinforcedAUTO
mode(thedefaultsettingtemperature
is24
Closethepanelfirmlytoitsoriginal
position.
Onceyoupushthemanualbutton,the
operationmodeisshiftedinanorderas:
AUTO,COOL,OFF.
Thisisusedfortestingpurposesonly.
Torestoretheremotecontrolleroperation,
usetheremotecontrollerdirectly.
CAUTION:
1
3
2
●
●
●
Mode
Coolingoperation
Heatingoperation Dryingoperation
Temperature
1.Ifairconditionerisusedoutsideoftheaboveconditions,certainsafetyprotectionfeatures
maycomeintooperationandcausetheunittofunctionabnormally.
2.Roomrelativehumiditylessthan80%.Iftheairconditioneroperatesinexcessofthis
figure,thesurfaceoftheairconditionermayattractcondensation.Pleasesetsthevertical
airflowlouvertoitsmaximumangle(verticallytothefloor),andsetHIGHfanmode.
3.Optimumperformancewillbeachievedwithintheseoperatingtemperature.
Roomtemperature
Outdoortemperature
NOTE:
1732
6290
030
3286
-724
2076
1843
64109
-54323109
Forthemodelswithlow
temperaturecoolingsystem
215270126
Forspecialtropicalmodels
10325090
(<21000Btu/hmodels)
(21000Btu/hmodels)
(<21000Btu/hmodels)
(21000Btu/hmodels)
(Forspecialtropicalmodels)
17326290
114352109
184364109
215270126
Manualcontrol
button
Panel
AUTO/COOL
Range
Range
Vertical
louver
(threeplaces)
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

OPERATINGINSTRUCTIONS
Airflowdirectioncontrol
Adjusttheairflowdirectionproperlyotherwise,it
mightcausediscomfortorcauseunevenroom
temperatures.
Adjustthehorizontallouverusingtheremote
controller.
Adjusttheverticallouvermanually.
Performthisfunctionwhiletheunitisinoperation.
Usetheremotecontrollertoadjusttheairflow
direction.Thehorizontallouvercanbemovedat
arangeof6foreachpress,orswingupanddown
automatically.PleaserefertotheREMOTE
CONTROLLEROPERATIONMANUALfordetails.
Tosettheverticalairflow(Up--Down)direction
O
Movetheverticallouvermanuallytoadjusttheairflow
inthedirectionyouprefer.
:Beforeadjustingtheverticallouvers,the
supplypowermustbedisconnected.
Forsomemodels,theverticallouvercanbeadjusted
byusingtheremotecontroller.Pleaserefertothe
REMOTECONTROLLEROPERATIONMANUAL
fordetails.
Tosetthehorizontalairflowdirection(left-right)
IMPORTANT
Donotoperatetheairconditionerforlongperiodswith
theairflowdirectionsetdownwardincoolingor
dehumidifyingmode.Otherwise,condensationmay
occuronthesurfaceofthehorizontallouvercausing
moisturetodropontothefloororonfurnishings.
Donotmovethehorizontallouvermanuallyunlessitis
necessary.Alwaysusetheremotecontroller.
Whentheairconditionerisstartedimmediatelyafterit
wasstopped,thehorizontallouvermightnotmovefor
approximately10seconds.
Openangleofthehorizontallouvershouldnotbeset
toosmall,asCOOLINGorHEATINGperformancemay
beimpairedduetotoorestrictedairflowarea.
Donotoperateunitwithhorizontallouverinclosed
position.
Whentheairconditionerisconnectedtopower(initial
power),thehorizontallouvermaygenerateasoundfor
10seconds,thisisanormaloperation.
CAUTION
,,
,,
,,
,,
Manuloperationcanbeusedtemporarilyincasetheremotecontrollerisdisableor
maintenancenecessary.
OPERATINGINSTRUCTIONS
Manualoperation
NOTE:ThismanualdoesnotincludeRemoteControllerOperations,seethe
<<RemoteControllerInstruction>>packedwiththeunitfordetails.
Operatingtemperature
Openandliftthefrontpaneluptoanangle
untilitremainsfixedwithaclickingsound.
PushthebuttonuntiltheAUTOindicator
islit,theunitwillworkinforcedAUTO
mode(thedefaultsettingtemperature
is24
Closethepanelfirmlytoitsoriginal
position.
Onceyoupushthemanualbutton,the
operationmodeisshiftedinanorderas:
AUTO,COOL,OFF.
Thisisusedfortestingpurposesonly.
Torestoretheremotecontrolleroperation,
usetheremotecontrollerdirectly.
CAUTION:
1
3
2
●
●
●
Mode
Coolingoperation
Heatingoperation Dryingoperation
Temperature
1.Ifairconditionerisusedoutsideoftheaboveconditions,certainsafetyprotectionfeatures
maycomeintooperationandcausetheunittofunctionabnormally.
2.Roomrelativehumiditylessthan80%.Iftheairconditioneroperatesinexcessofthis
figure,thesurfaceoftheairconditionermayattractcondensation.Pleasesetsthevertical
airflowlouvertoitsmaximumangle(verticallytothefloor),andsetHIGHfanmode.
3.Optimumperformancewillbeachievedwithintheseoperatingtemperature.
Roomtemperature
Outdoortemperature
NOTE:
1732
6290
030
3286
-724
2076
1843
64109
-54323109
Forthemodelswithlow
temperaturecoolingsystem
215270126
Forspecialtropicalmodels
10325090
(<21000Btu/hmodels)
(21000Btu/hmodels)
(<21000Btu/hmodels)
(21000Btu/hmodels)
(Forspecialtropicalmodels)
17326290
114352109
184364109
215270126
Manualcontrol
button
Panel
AUTO/COOL
Range
Range
Vertical
louver
(threeplaces)
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

CleaningtheGrille,CaseandRemoteController
Aclothdampenedwithcoldwatermaybeused
ontheindoorunitifitisverydirty.Thenwipeit
withadrycloth.
Donotuseachemicallytreatedclothordusterto
cleantheunit.
Donotusebenzine,thinner,polishingpowder,or
similarsolventsforcleaning.Thesemaycause
theplasticsurfacetocrackordeform.
Neverusewaterhotterthan40C/104OFtoclean
thefrontpanel,itcouldcausedeformationof
discoloration.
CAUTIONS
CAREANDMAINTENANCE
Careandmaintenance
Turnthesystemoffbeforecleaning.Toclean,wipewith
asoft,drycloth.Donotusebleachorabrasives.
NOTE:Supplypowermustbedisconnectdbefore
cleaningtheindoorunit.
FilterHandle
Acloggedairfilterreducesthecoolingefficiencyof
thisunit.Pleasecleanthefilteronceevery2weeks.
1.Lifttheindoorunitpaneluptoanangleuntilit
stopswithaclickingsound.
2.Takeholdofthehandleoftheairfilterandliftit
upslightlytotakeitoutfromthefilterholder,
thenpullitdownwards.
3.RemovetheAIRFILTERfromtheindoorunit.
CleantheAIRFILTERoncetwoweeks.
CleantheAIRFILTERwithavacuumcleaner
orwater,thendryitupincoolplace.
Cleaningtheairfilter
.
.
OPERATINGINSTRUCTIONS
Howtheairconditionerworks
1hour
1hour
Set
Temperature
Set
Temperature
Cooling
Heating
SLEEPoperation
1hour
1hour
SLEEPoperation
7hourstimeroff
7hourstimeroff
AUTOoperation
SLEEPoperation
DRYINGoperation
Optimaloperation
WhenyousettheairconditionerinAUTOmode,itwill
automaticallyselectcooling,heating(cooling/heating
modelsonly),orfanonlyoperationdependingonwhat
temperatureyouhaveselectedandtheroom
temperature.
Theairconditionerwillcontrolroomtemperature
automaticallyroundthetemperaturepointsetbyyou.
IftheAUTOmodeisuncomfortable,youcanselect
desiredconditionsmanually.
WhenyoupushSLEEPbuttononremotecontroller
duringcooling,heating(cooling&heatingmodelsonly),
orAUTOoperation,theairconditionerwill
automaticallyincrease(cooling)ordecrease(heating)
perhourforthefirst2hours,thenhold
steadyforthenext5hours,afterthatitwillswitchoff.
Thischaracteristicmaintainsbothenerysavingand
comfortinnightoperation.
Thetemperatureisregulatedwhiledehumidifyingby
repeatingturningonandoffofthecoolingoperationor
fanonly.ThefanspeedisLOW.
Toachieveoptimalperformance,pleasenotethe
following:
Adjusttheairflowdirectioncorrectlysothatitisnot
directedonpeople.
Adjustthetemperaturetoachievethehighestcomfort
level.Donotadjusttheunittoexcessivetemperature
levels.
ClosedoorsandwindowsonCOOLorHEATmodes,
orperformancemaybereduced.
UseTIMERONbuttonontheremotecontrollerto
selectatimeyouwanttostartyourairconditioner.
Donotputanyobjectnearairinletorairoutlet,asthe
efficiencyoftheairconditionermaybereducedand
theairconditionermaystoprunning.
Cleantheairfilterperiodically,otherwisecoolingor
heatingperformancemaybereduced.
Donotoperateunitwithhorizontallouvreinclosed
position.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

CleaningtheGrille,CaseandRemoteController
Aclothdampenedwithcoldwatermaybeused
ontheindoorunitifitisverydirty.Thenwipeit
withadrycloth.
Donotuseachemicallytreatedclothordusterto
cleantheunit.
Donotusebenzine,thinner,polishingpowder,or
similarsolventsforcleaning.Thesemaycause
theplasticsurfacetocrackordeform.
Neverusewaterhotterthan40C/104OFtoclean
thefrontpanel,itcouldcausedeformationof
discoloration.
CAUTIONS
CAREANDMAINTENANCE
Careandmaintenance
Turnthesystemoffbeforecleaning.Toclean,wipewith
asoft,drycloth.Donotusebleachorabrasives.
NOTE:Supplypowermustbedisconnectdbefore
cleaningtheindoorunit.
FilterHandle
Acloggedairfilterreducesthecoolingefficiencyof
thisunit.Pleasecleanthefilteronceevery2weeks.
1.Lifttheindoorunitpaneluptoanangleuntilit
stopswithaclickingsound.
2.Takeholdofthehandleoftheairfilterandliftit
upslightlytotakeitoutfromthefilterholder,
thenpullitdownwards.
3.RemovetheAIRFILTERfromtheindoorunit.
CleantheAIRFILTERoncetwoweeks.
CleantheAIRFILTERwithavacuumcleaner
orwater,thendryitupincoolplace.
Cleaningtheairfilter
.
.
OPERATINGINSTRUCTIONS
Howtheairconditionerworks
1hour
1hour
Set
Temperature
Set
Temperature
Cooling
Heating
SLEEPoperation
1hour
1hour
SLEEPoperation
7hourstimeroff
7hourstimeroff
AUTOoperation
SLEEPoperation
DRYINGoperation
Optimaloperation
WhenyousettheairconditionerinAUTOmode,itwill
automaticallyselectcooling,heating(cooling/heating
modelsonly),orfanonlyoperationdependingonwhat
temperatureyouhaveselectedandtheroom
temperature.
Theairconditionerwillcontrolroomtemperature
automaticallyroundthetemperaturepointsetbyyou.
IftheAUTOmodeisuncomfortable,youcanselect
desiredconditionsmanually.
WhenyoupushSLEEPbuttononremotecontroller
duringcooling,heating(cooling&heatingmodelsonly),
orAUTOoperation,theairconditionerwill
automaticallyincrease(cooling)ordecrease(heating)
perhourforthefirst2hours,thenhold
steadyforthenext5hours,afterthatitwillswitchoff.
Thischaracteristicmaintainsbothenerysavingand
comfortinnightoperation.
Thetemperatureisregulatedwhiledehumidifyingby
repeatingturningonandoffofthecoolingoperationor
fanonly.ThefanspeedisLOW.
Toachieveoptimalperformance,pleasenotethe
following:
Adjusttheairflowdirectioncorrectlysothatitisnot
directedonpeople.
Adjustthetemperaturetoachievethehighestcomfort
level.Donotadjusttheunittoexcessivetemperature
levels.
ClosedoorsandwindowsonCOOLorHEATmodes,
orperformancemaybereduced.
UseTIMERONbuttonontheremotecontrollerto
selectatimeyouwanttostartyourairconditioner.
Donotputanyobjectnearairinletorairoutlet,asthe
efficiencyoftheairconditionermaybereducedand
theairconditionermaystoprunning.
Cleantheairfilterperiodically,otherwisecoolingor
heatingperformancemaybereduced.
Donotoperateunitwithhorizontallouvreinclosed
position.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

OPERATIONTIPS
Thefollowingeventsmayoccurduringnormaloperation.
1.
Thecompressorcan'trestartfor3-4minutesafteritstops.
TheunitisdesignednottoblowcoldaironHEATmode,whentheindoorheatexchangerisin
oneofthefollowingthreesituationsandthesettemperaturehasnotbeenreached.
A)Whenheatinghasjuststarting.
B)Defrosting.
C)Lowtemperatureheating.
Theindoororoutdoorfanstoprunningwhendefrosting(Coolingandheatingmodelsonly).
Frostmaybegeneratedontheoutdoorunitduringheatcyclewhenoutdoortemperatureislow
andhumidityishighresultinginlowerheatingefficiencyoftheairconditioner.
Duringthisconditionairconditionerwillstopheatingoperationandstartdefrostingautomatically.
Thetimetodefrostmayvaryfrom4to10minutesaccordingtotheoutdoortemperatureand
theamountoffrostbuildupontheoutdoorunit.
2.
Awhitemistmaygenerateduetoalargetemperaturedifferencebetweenairinletandairoutlet
onCOOLmodeinanindoorenvironmentthathasahighrelativehumidity.
Awhitemistmaygenerateduetomoisturegeneratedfromdefrostingprocesswhentheair
conditionerrestartsinHEATmodeoperationafterdefrosting.
3.
Youmayhearalowhissingsoundwhenthecompressorisrunningorhasjuststoppedrunning.
Thissoundisthesoundoftherefrigerantflowingorcomingtoastop.
Youcanalsohearalow"squeak"soundwhenthecompressorisrunningorhasjuststopped
running.Thisiscausedbyheatexpansionandcoldcontractionoftheplasticpartsintheunit
whenthetemperatureischanging.
Anoisemaybeheardduetolouverrestoringtoitsoriginalpositionwhenpowerisfirstturnedon.
4.
Thisisanormalconditionwhentheairconditionerhasnotbeenusedforalongtimeorduringfirst
useoftheunit.
5.
Thisiscausedbytheindoorunitgivingoffsmellspermeatedfrombuildingmaterial,fromfurniture,
orsmoke.
Protectionoftheairconditioner.
Compressorprotection
Anti-coldair(Coolingandheatingmodelsonly)
Defrosting(Coolingandheatingmodelsonly)
Awhitemistcomingoutfromtheindoorunit
Lownoiseoftheairconditioner
Dustisblownoutfromtheindoorunit.
Apeculiarsmellcomesoutfromtheindoorunit.
6.
Whenindoortemperaturereachesthetemperaturesettingonairconditioner,thecompressorwill
stopautomatically,andtheairconditionerturnstoFANonlymode.Thecompressorwillstartagain
whentheindoortemperaturerisesonCOOLmodeorfallsonHEATmode(Forcoolingandheating
modelsonly)tothesetpoint.
TheairconditionerturnstoFANonlymodefromCOOLorHEAT(Forcoolingand
heatingmodelsonly)mode.
CAREANDMAINTENANCE
Maintenance
Checksbeforeoperation
Ifyouplantoidletheunitforalongtime,perform
thefollowing:
(1)Operatethefanforabouthalfadaytodrythe
insideoftheunit.
(2)Stoptheairconditioneranddisconnectpower.
(3)Theoutdoorunitrequiresperiodicmaintenance
andcleaning.Donotattempttodothisyourself.
Contactyourdealerorservicer.
Removethebatteriesfromtheremotecontroller.
Checkthatthewiringisnotbrokenoffor
disconnected.
Checkthattheairfilterisinstalled.
Checkiftheairoutletorinletisblockedafterthe
airconditionerhasnotbeenusedforalongtime.
Donottouchthemetalpartsoftheunitwhen
removingthefilter.Injuriescanoccurwhen
handlingsharpmetaledges.
Donotusewatertocleaninsidetheairconditioner.
Exposuretowatercandestroytheinsulation,
leadingtopossibleelectricshock.
Whencleaningtheunit,firstmakesurethatthe
powerandcircuitbreakerareturnedoff.
Caution
1
2
4.RemovetheAirFresheningFilterfromitssupport
frame(onsomemodels).
(Theoptionalfilterinclude:PlasmaDustCollector/
SilverIonfilter/Biofilter/VitaminCfilter/3Mair
purifierfilter,etc.Theremovingandinstallation
methodsareslightlydifferent,seethepictures
markedandontheleft.
Cleantheairfresheningfilteratleastoncea
month,andreplaceitevery4-5months.
Cleanitwithvacuumcleaner,thendryitincool
place.
5.Installtheairfresheningfilterbackintoposition.
6.Inserttheupperportionofairfilterbackintothe
unit,takingcarethattheleftandrightedgesline
upcorrectlyandplacefilterintoposition.
.
.
1 2
DonottouchthePlasmaDustCollector
Filterwithin10minutesafteropeningthe
frontpanel,itmaycauseanelectricshock.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

OPERATIONTIPS
Thefollowingeventsmayoccurduringnormaloperation.
1.
Thecompressorcan'trestartfor3-4minutesafteritstops.
TheunitisdesignednottoblowcoldaironHEATmode,whentheindoorheatexchangerisin
oneofthefollowingthreesituationsandthesettemperaturehasnotbeenreached.
A)Whenheatinghasjuststarting.
B)Defrosting.
C)Lowtemperatureheating.
Theindoororoutdoorfanstoprunningwhendefrosting(Coolingandheatingmodelsonly).
Frostmaybegeneratedontheoutdoorunitduringheatcyclewhenoutdoortemperatureislow
andhumidityishighresultinginlowerheatingefficiencyoftheairconditioner.
Duringthisconditionairconditionerwillstopheatingoperationandstartdefrostingautomatically.
Thetimetodefrostmayvaryfrom4to10minutesaccordingtotheoutdoortemperatureand
theamountoffrostbuildupontheoutdoorunit.
2.
Awhitemistmaygenerateduetoalargetemperaturedifferencebetweenairinletandairoutlet
onCOOLmodeinanindoorenvironmentthathasahighrelativehumidity.
Awhitemistmaygenerateduetomoisturegeneratedfromdefrostingprocesswhentheair
conditionerrestartsinHEATmodeoperationafterdefrosting.
3.
Youmayhearalowhissingsoundwhenthecompressorisrunningorhasjuststoppedrunning.
Thissoundisthesoundoftherefrigerantflowingorcomingtoastop.
Youcanalsohearalow"squeak"soundwhenthecompressorisrunningorhasjuststopped
running.Thisiscausedbyheatexpansionandcoldcontractionoftheplasticpartsintheunit
whenthetemperatureischanging.
Anoisemaybeheardduetolouverrestoringtoitsoriginalpositionwhenpowerisfirstturnedon.
4.
Thisisanormalconditionwhentheairconditionerhasnotbeenusedforalongtimeorduringfirst
useoftheunit.
5.
Thisiscausedbytheindoorunitgivingoffsmellspermeatedfrombuildingmaterial,fromfurniture,
orsmoke.
Protectionoftheairconditioner.
Compressorprotection
Anti-coldair(Coolingandheatingmodelsonly)
Defrosting(Coolingandheatingmodelsonly)
Awhitemistcomingoutfromtheindoorunit
Lownoiseoftheairconditioner
Dustisblownoutfromtheindoorunit.
Apeculiarsmellcomesoutfromtheindoorunit.
6.
Whenindoortemperaturereachesthetemperaturesettingonairconditioner,thecompressorwill
stopautomatically,andtheairconditionerturnstoFANonlymode.Thecompressorwillstartagain
whentheindoortemperaturerisesonCOOLmodeorfallsonHEATmode(Forcoolingandheating
modelsonly)tothesetpoint.
TheairconditionerturnstoFANonlymodefromCOOLorHEAT(Forcoolingand
heatingmodelsonly)mode.
CAREANDMAINTENANCE
Maintenance
Checksbeforeoperation
Ifyouplantoidletheunitforalongtime,perform
thefollowing:
(1)Operatethefanforabouthalfadaytodrythe
insideoftheunit.
(2)Stoptheairconditioneranddisconnectpower.
(3)Theoutdoorunitrequiresperiodicmaintenance
andcleaning.Donotattempttodothisyourself.
Contactyourdealerorservicer.
Removethebatteriesfromtheremotecontroller.
Checkthatthewiringisnotbrokenoffor
disconnected.
Checkthattheairfilterisinstalled.
Checkiftheairoutletorinletisblockedafterthe
airconditionerhasnotbeenusedforalongtime.
Donottouchthemetalpartsoftheunitwhen
removingthefilter.Injuriescanoccurwhen
handlingsharpmetaledges.
Donotusewatertocleaninsidetheairconditioner.
Exposuretowatercandestroytheinsulation,
leadingtopossibleelectricshock.
Whencleaningtheunit,firstmakesurethatthe
powerandcircuitbreakerareturnedoff.
Caution
1
2
4.RemovetheAirFresheningFilterfromitssupport
frame(onsomemodels).
(Theoptionalfilterinclude:PlasmaDustCollector/
SilverIonfilter/Biofilter/VitaminCfilter/3Mair
purifierfilter,etc.Theremovingandinstallation
methodsareslightlydifferent,seethepictures
markedandontheleft.
Cleantheairfresheningfilteratleastoncea
month,andreplaceitevery4-5months.
Cleanitwithvacuumcleaner,thendryitincool
place.
5.Installtheairfresheningfilterbackintoposition.
6.Inserttheupperportionofairfilterbackintothe
unit,takingcarethattheleftandrightedgesline
upcorrectlyandplacefilterintoposition.
.
.
1 2
DonottouchthePlasmaDustCollector
Filterwithin10minutesafteropeningthe
frontpanel,itmaycauseanelectricshock.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

TROUBLESHOOTINGTIPS
TroubleshootingTips
Malfunctions
Unitdoesnot
start
Unitnotcooling
orheating
(Cooling/heating
modelsonly)
roomverywell
whileairflowing
outfromtheair
condtioneri
Cause
Powercut
Unitmayhavebecome
unplugged.
Fusemayhaveblown.
BatteryinRemotecontrollermay
havebeenexhausted.
Thetimeyouhavesetwithtimer
isincorrect.
Waitforpowertoberestored.
Checkthatplugissecurelyinwall
receptacle.
Replacethefuse.
Replacethebattery.
Waitorcanceltimersetting.
Settemperaturecorrectly.For
detailedmethodpleasereferto
""Usingremotecontrolsection.
Cleantheairfilter.
Closethedoorsorwindows.
Clearobstructionsawayfirst,then
restarttheunit.
Wait.
Inappropriatetemperature
setting.
Airfilterisblocked.
DoorsorWindowsareopen.
Airinletoroutletofindooror
outdoorunithasbeenblocked.
Compressor3or4minutes
protectionhasbeenactivated.
Ifthetroublehasnotbeencorrected,pleasecontactalocaldealerorthenearestcustomer
servicecenter.Besuretoinformthemofthedetailedmalfunctionsandunitmodel.
Notes:Donotattempttorepairtheunityourself.
Alwaysconsultanauthorisedserviceprovider.
Whatshouldbedone?
7.Drippingwatermaygenerateonthesurfaceoftheindoorunitwhencoolinginahigh
relativelyhumidity(relativehumidityhigherthan80%).Adjustthehorizontallouverto
themaximumairoutletpositionandselectHIGHfanspeed.
8.
Theairconditionerdrawsinheatfromtheoutdoorunitandreleasesitviatheindoorunit
duringheatingoperation.Whentheoutdoortemperaturefalls,heatdrawninbytheair
conditionerdecreasesaccordingly.Atthesametime,heatloadingoftheairconditioner
increasesduetolargerdifferencebetweenindoorandoutdoortemperature.Ifa
comfortabletemperaturecan'tbeachievedbytheairconditioner,wesuggestyouusea
supplementaryheatingdevice.
9.
Powerfailureduringoperationwillstoptheunitcompletely.
FortheunitwithoutAuto-restartfeature,whenthepowerrestores,theOPERATIONindicator
ontheindoorunitstartsflashing.Torestarttheoperation,pushtheON/OFFbuttononthe
remotecontroller.FortheunitwithAuto-restartfeature,whenthepowerrestores,theunit
restartsautomaticallywithalltheprevioussettingspreservedbythememoryfunction.
Forsomemodels,themachineisspecialdesignedwithAuto-restartfunctionfortheopenangle
ofthehorizontallouver.PowerfailureduringoperationorpressingtheON/OFFbuttononthe
remotecontrollerwillstoptheunitcompletely.WhenthepowerrestoresorpressingtheON/OFF
buttonontheremotecontrolleragain,theunitrestartsautomaticallywithalltheprevioussettings
includingtheopenangleofthehorizontallouverbythememoryfunction.Sowestronglysuggest
thattheopenangleofthehorizontallouvershouldnotbesettoosmall,incasethecondensed
waterformsanddropsfromthehorizontallouver.PresstheAUTO/COOLbuttonunderthe
frontpanelandtheopenangleofthehorizontallouverwillberestoredtothestandardangle
whenthecondensedwaterformsonthehorizontallouver.
10.Lightningoracarwirelesstelephoneoperatingnearbymaycausetheunittomalfunction.
Disconnecttheunitwithpowerandthenre-connecttheunitwithpoweragain.Pushthe
ON/OFFbuttonontheremotecontrollertorestartoperation.
Heatingmode(Forcoolingandheatingmodelsonly)
Auto-restartfunction
OPERATIONTIPS
Stoptheairconditionerimmediatelyifoneofthefollowingfaultsoccur.Disconnectthe
powerandcontactthenearestcustomerservicecenter.
Fuseblowsfrequentlyorcircuitbreakertripsfrequently.
Otherobjectsorwaterpenetratetheairconditioner.
Theremotecontrollerwon'tworkorworksabnormally.
Trouble
OPERATION/RUNindicatororotherindicatorscontinueflashingand
thisflashcan'tbefixedbydisconnectingthepower,andthenconnectitinagain.
Ifoneofthefollowingcodeappearsonthedisplayarea:
E0,E1,E2,E3.....orP0,P1,P2,P3......
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

TROUBLESHOOTINGTIPS
TroubleshootingTips
Malfunctions
Unitdoesnot
start
Unitnotcooling
orheating
(Cooling/heating
modelsonly)
roomverywell
whileairflowing
outfromtheair
condtioneri
Cause
Powercut
Unitmayhavebecome
unplugged.
Fusemayhaveblown.
BatteryinRemotecontrollermay
havebeenexhausted.
Thetimeyouhavesetwithtimer
isincorrect.
Waitforpowertoberestored.
Checkthatplugissecurelyinwall
receptacle.
Replacethefuse.
Replacethebattery.
Waitorcanceltimersetting.
Settemperaturecorrectly.For
detailedmethodpleasereferto
""Usingremotecontrolsection.
Cleantheairfilter.
Closethedoorsorwindows.
Clearobstructionsawayfirst,then
restarttheunit.
Wait.
Inappropriatetemperature
setting.
Airfilterisblocked.
DoorsorWindowsareopen.
Airinletoroutletofindooror
outdoorunithasbeenblocked.
Compressor3or4minutes
protectionhasbeenactivated.
Ifthetroublehasnotbeencorrected,pleasecontactalocaldealerorthenearestcustomer
servicecenter.Besuretoinformthemofthedetailedmalfunctionsandunitmodel.
Notes:Donotattempttorepairtheunityourself.
Alwaysconsultanauthorisedserviceprovider.
Whatshouldbedone?
7.Drippingwatermaygenerateonthesurfaceoftheindoorunitwhencoolinginahigh
relativelyhumidity(relativehumidityhigherthan80%).Adjustthehorizontallouverto
themaximumairoutletpositionandselectHIGHfanspeed.
8.
Theairconditionerdrawsinheatfromtheoutdoorunitandreleasesitviatheindoorunit
duringheatingoperation.Whentheoutdoortemperaturefalls,heatdrawninbytheair
conditionerdecreasesaccordingly.Atthesametime,heatloadingoftheairconditioner
increasesduetolargerdifferencebetweenindoorandoutdoortemperature.Ifa
comfortabletemperaturecan'tbeachievedbytheairconditioner,wesuggestyouusea
supplementaryheatingdevice.
9.
Powerfailureduringoperationwillstoptheunitcompletely.
FortheunitwithoutAuto-restartfeature,whenthepowerrestores,theOPERATIONindicator
ontheindoorunitstartsflashing.Torestarttheoperation,pushtheON/OFFbuttononthe
remotecontroller.FortheunitwithAuto-restartfeature,whenthepowerrestores,theunit
restartsautomaticallywithalltheprevioussettingspreservedbythememoryfunction.
Forsomemodels,themachineisspecialdesignedwithAuto-restartfunctionfortheopenangle
ofthehorizontallouver.PowerfailureduringoperationorpressingtheON/OFFbuttononthe
remotecontrollerwillstoptheunitcompletely.WhenthepowerrestoresorpressingtheON/OFF
buttonontheremotecontrolleragain,theunitrestartsautomaticallywithalltheprevioussettings
includingtheopenangleofthehorizontallouverbythememoryfunction.Sowestronglysuggest
thattheopenangleofthehorizontallouvershouldnotbesettoosmall,incasethecondensed
waterformsanddropsfromthehorizontallouver.PresstheAUTO/COOLbuttonunderthe
frontpanelandtheopenangleofthehorizontallouverwillberestoredtothestandardangle
whenthecondensedwaterformsonthehorizontallouver.
10.Lightningoracarwirelesstelephoneoperatingnearbymaycausetheunittomalfunction.
Disconnecttheunitwithpowerandthenre-connecttheunitwithpoweragain.Pushthe
ON/OFFbuttonontheremotecontrollertorestartoperation.
Heatingmode(Forcoolingandheatingmodelsonly)
Auto-restartfunction
OPERATIONTIPS
Stoptheairconditionerimmediatelyifoneofthefollowingfaultsoccur.Disconnectthe
powerandcontactthenearestcustomerservicecenter.
Fuseblowsfrequentlyorcircuitbreakertripsfrequently.
Otherobjectsorwaterpenetratetheairconditioner.
Theremotecontrollerwon'tworkorworksabnormally.
Trouble
OPERATION/RUNindicatororotherindicatorscontinueflashingand
thisflashcan'tbefixedbydisconnectingthepower,andthenconnectitinagain.
Ifoneofthefollowingcodeappearsonthedisplayarea:
E0,E1,E2,E3.....orP0,P1,P2,P3......
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

Beforeusingyourairconditioner,pleaseread
thismanualcarefullyandkeepitforfuturereference.
ROOMAIRCONDITIONER
ReadThisManual
Insideyouwillfindmanyhelpfulhintsonhow
touseandmaintainyourairconditionerproperly.
Justalittlepreventativecareonyourpartcan
saveyouagreatdealoftimeandmoneyover
thelifeofyourairconditioner.You'llfindmany
answerstocommonproblemsinthechartof
troubleshootingtips.Ifyoureviewthechartof
TroubleshootingTipsfirst,youmaynotneed
tocallforservice.
Thedesignandspecificationsaresubjecttochangewithoutpriornoticefor
productimprovement.Consultwiththesalesagencyormanufacturerfordetails.
SPLITTYPE-
CS503U-C8
202000192036
20110618
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn
