,_ WARNING
Personal Injury Hazard
Always turn off and unplug the vacuum
cleaner before cleaning the agitator area
as agitator may suddenly restart. Failure
todo socan resultin personal injury.
OVERLOAD PROTECTOR
The PowerMate has built-in protection
against motor and belt damage shouldthe
agitator jam. If the agitator slows clown or
stops, the overload protector shuts off the
PowerMate. The canister motor will continue
to run.
OVERLOAD
PROTECTOR
RESET-
Tocorrect problem: Turn off and unplug
vacuum cleaner, remove obstruction, then
press OVERLOAD PROTECTOR RESET
button.
If the problem persists,have the vacuum
cleaner serviced by a Sears or other
qualified service agent.
ELECTRONIC SUCTION CONTROL
The electronic suction control allows you to
change the power of the vacuum cleaner
suction motor.
SUCTION Increase suction
CONTROL Increase for upholsteries
,_ Suction and carpets.
m_ Decrease suction
Decrease for draperies and
Suction lightweight rugs.
CHECK BAG INDICATOR
When the vacuum cleaner is running with
normal airflow, the light on the CHECK
BAG indicator is off. The light comes on
whenever the airflow becomes blocked.
If that occurs, check the disposable dust
bag, motor safety filter and other
possible clog locations shown in
REMOVING CLOGS (page 16).
Indicator
To correct problem: See "Check Bag
Indicator activates" in
TROUBLESHOOTING (page 24).
NOTE: The light may come on when using
certain attachments, due to reduced airflow
through attachment.
THERMAL PROTECTOR
This vacuum cleaner has a thermal
protector which automatically trips to
protect the vacuum cleaner from
overheating. If a clog prevents the normal
flow of air to the motor, the thermal
protector turns the motor off
automatically. This allows the motor to
cool in order to prevent possible damage
to the vacuum cleaner.
Tocorrect problem: Turn off and unplug
vacuum cleaner to allow the vacuum
cleaner to cool and the thermal protector
to reset. Check for and remove clogs, if
necessary. Also check and replace any
clogged filters. Wait approximately fifty
(50) minutes and plug the vacuum cleaner
in and turn back on to see if the motor
protector has reset.
If the problem persists,have the vacuum
cleaner serviced by a Sears or other
qualified service agent.
-15-