12
OPERATION INSTRUCTIONS
BEFORE USING YOUR APPLIANCE
Remove the exterior and interior packing
Before connecting the appliance to the power source, let it stand upright for approximately 4 hours. This will reduce
the possibility of a malfunction in the cooling system from handling during transportation
SWITCHING ON/OFF THE AIR CONDITIONER
The appliance can be switched ON or OFF by pressing the POWER button on the control panel or the ON/OFF but-
ton on the remote control
COOLING MODE
In this mode, the air conditioner cools and dehumidifies the room. To activate this function mode, press the
Mode Control until the Cooling indicator light comes on. When the cooling mode is set, the compressor will start
in approximately 3 minutes. In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust
hose must be connected to exhaust out the hot air.
The tem- perature setting range of this air conditioner is from 61°F / 16°C to 89°F / 32°C. To set the temper-
ature, press the or buttons. This air conditioner has a 5°F temperature cushion which if the set tempera-
ture is within 5°F of the ambient temperature, the unit runs on fan only mode. This saves energy and prolongs the life
of the compressor of the air conditioner.
To set the fan speed, press the FAN button. In cooling mode, the difference in noise level between the 3 fan speeds
is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear
the difference between high and low fan speed settings.
A dual hose portable air conditioner will cool a room faster and will help minimize negative air pressure situation in
the room. If the outside temperature is much higher or more humid than the room, the intake hose can be covered
with the included cover and it will function like a single hose unit.
DEHUMIDIFYING ONLY MODE
In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently de-
pending on the ambi- ent temperature and the fan speed is set to LOW. To activate this function mode, press
the Mode Control until the Dehumidifying indicator light comes on. Please note that when switching function mode,
there will be an approximately 3 minute transition time. In dehumidifying mode, do not connect the exhaust hose and
let the warm air return to the room. If room temperature is higher than 77°F, the fan speed can be adjusted. If room
temperature is lower than 77°F, the fan speed is set at Low.
NOTE: When using the Dehumidifying mode, the exhaust and intake hoses should not be vented to the outside. If
the warm air is exhausted to the outside, cooling may occur. Additionally, you must manually drain the water from the
unit.
FAN ONLY MODE
In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode,
press the MODE button until the Fan indicator light comes on. In this function mode, the temperature cannot be set.
Subsequently, set the desired fan speed by pressing the Fan button. Fan Only mode does not require the use of both
exhaust and intake hoses.