26932 Parameter and Command Class List
Parameter
number
Parameter: Length Valid value Description
1
Timeout Duration
1
0, 1, 5(default), 15, 30
and 0xFF(-1)
0=Test(5S)
1=1 minute
5=5 minutes
15=15 minutes
30=30 minutes
0xFF=Disable timeout
2
Change brightness of
associated light bulb(s).
1
0x00-0x63, 0xFF(default) 0xFF = last dimming level
3
Operation Mode
1
1,2,3(default)
1=Manual
2=Vacancy
3= Occupancy
5
Invert Switch 1 0 (default), 1 In a 3-way configuration,
invert the connected Add-On
Switch buttons
0=Disabled
1=Enable
6
Enable/Disable Motion Sensor
1 0, 1 (default) 0=Disabled
1=Enable
7
Adjust steps/levels with
Remote
1 1(default)-99
8
Adjust timing of steps/levels
with Remote
2 1,
2,3(default),4-00FF(255)
9
Adjust steps/levels
1
1(default)-99
10
Adjust timing of steps/levels 2 1, 2,3(default),
4-00FF(255)
11
Adjust Steps/levels with ALL
ON/OFF” command
1 1(default)-99
12
Adjust timing of steps/levels
with ALL ON/OFF” command
2 1, 2,3(default),
4-00FF(255)
13 Motion sensing sensitivity 1 1,2(default),3 1=High sensitivity
2=Medium sensitivity
3=Low sensitivity
14
Enable/Disable Light Sensing 1 0(default), 1 0=Disabled
1=Enabled
15
Reset cycle 2 0, 1 ,2(default),3,
4, ,110
0=Disable
1=10 seconds
2=20 seconds
3=30 seconds
4=45 seconds
110 =27 mins 15 seconds
16
Switch Mode 1 0 (default), 1 0=Disabled
1=Enabled
17
Switch Level 1 0(default)-99 0=Disabled
1=Level 1
99=Level 99(full brightness)