Installation Instructions Section 2
8
Part Number 000006520 Rev 03 12/19
Maximum Breaker Size & Minimum Circuit Amperage Chart.
Due to continuous improvements, this information is for reference only. Please refer to the ice machine serial number
tag to verify electrical data. Serial tag information overrides information listed on this page
Ice Machine
Voltage/
Phase/
Cycle
Air-Cooled Water Cooled Remote
Maximum
Fuse/Circuit
Breaker
Minimum
Circuit Amps
Maximum
Fuse/Circuit
Breaker
Minimum
Circuit Amps
Maximum
Fuse/Circuit
Breaker
Minimum
Circuit Amps
S300
115/1/60 25 15.6 25 14.8 N/A N/A
230/1/50 15 7.4 15 6.9 N/A N/A
230/1/60 15 6.7 15 6.3 N/A N/A
S320
115/1/60 15 11.3 15 10.5 N/A N/A
208-230/1/60 15 6.0 15 5.6 N/A N/A
230/1/50 15 6.0 15 5.6 N/A N/A
S420/S450
115/1/60 20 14.2 20 13.5 N/A N/A
208-230/1/60 15 6.1 15 5.7 N/A N/A
230/1/50 15 7.1 15 6.8 N/A N/A
S500
115/1/60 20 20.0 20 13.5 25 20.0
208-230/1/60 15 6.1 15 5.7 15 8.3
230/1/50 15 7.1 15 6.8 15 6.7
S600
208-230/1/60 15 8.3 15 7.9 15 8.9
230/1/50 15 6.7 15 6.1 15 7.1
S850
208-230/1/60 20 11.9 20 10.9 20 11.9
208-230/3/60 15 9.2 15 8.2 15 9.2
230/1/50 20 10.8 20 9.4 15 10.4
S1000
208-230/1/60
30 17.3 30 16.3 25 15.7
208-230/3/60
15 10.6 15 9.6 15 10.6
230/1/50
20 12.7 20 11.3 20 12.3
460/3/60
N/A N/A 15 4.5 N/A N/A
S1200
208-230/1/60
35 25.0 35 25.0 N/A N/A
208-230/3/60
20 16.0 20 16.0 N/A N/A
230/1/50
30 20.0 30 20.0 N/A N/A
S1400
208-230/1/60 30 18.3 30 16.9 30 17.9
208-230/3/60 20 13.2 20 11.8 20 12.8
230/1/50 30 15.1 30 13.7 30 14.7
440-480/3/60 N/A N/A 15 6.4 N/A N/A
S1600
208-230/1/60 30 19.8 30 18.4 30 19.4
208-230/3/60 20 13.5 20 12.1 20 13.1
230/1/50 30 16.7 30 15.3 30 16.3
S1800
208-230/1/60
40 23.8 40 22.4 40 23.4
208-230/3/60
25 15.4 25 14.0 25 15.0
230/1/50
40 21.9 40 20.5 40 21.5
S3300
208-230/1/60
N/A N/A N/A N/A N/A N/A
208-230/3/60
N/A N/A 30 30 N/A N/A
230/1/50
N/A N/A N/A N/A N/A N/A
440-480/3/60
N/A N/A 15 9.9 N/A N/A
ST3000 208-230/3/60
N/A N/A 30 30 N/A N/A
S3300/ST3000 - Verify the direction of rotation correct is correct on the 3ph scroll compressor. The ice machine will have high suction pressure, low discharge pres-
sure and will be noticeably loud. Reverse any two incoming power leads to reverse rotation.