Section 2 Installation Instructions
Part Number 000006520 Rev 03 12/19 11
Remote Condenser/Line Set Installation
REMOTE ICE MACHINES
REFRIGERANT CHARGE
Each remote ice machine ships from the factory with a
refrigerant charge appropriate for installation with line
sets of up to 50' (15.25 m). The serial tag on the ice
machine indicates the refrigerant charge.
Additional refrigerant may be required for installations
using line sets between 50' and 100' (15.25-30.5 m)
long. If additional refrigerant is required, refer to the
chart below for the correct amount to be added.
Ice Machine
Remote Single
Circuit
Condenser
Line Set*
S500 JC0495
RT-20-R404A
RT-35-R404A
RT-50-R404A
S600/S800/S1000 JC0895
RT-20-R404A
RT-35-R404A
RT-50-R404A
S1400/S1600/
S1800
JC1395
RL-20-R404A
RL-35-R404A
RL-50-R404A
*Line Set Discharge Line Liquid Line
RT 1/2" (1.27 cm) 5/16" (.79 cm)
RL 1/2" (1.27 cm) 3/8" (.95 cm)
Air Temperature Around the Condenser
Minimum Maximum
-20°F (-29°C) 120°F (49°C)
Important
Manitowoc remote systems are only approved and
warranted as a complete new package. Warranty on
the refrigeration system will be void if a new ice
machine head section is connected to pre-existing
(used) tubing or remote condensers.
Important
EPA CERTIFIED TECHNICIANS
If remote line set length is between 50' and 100'
(15.25 and 30.5 m), add additional refrigerant to the
nameplate charge. Refer to the table below for the
model being worked on.
Tubing length: __________________________________
Refrigerant added to nameplate: ___________________
New total refrigerant charge: ______________________
!
Warning
Potential Personal Injury Situation
The ice machine contains refrigerant charge.
Installation of the line sets must be performed by a
properly trained and EPA certified refrigeration
technician aware of the dangers of dealing with
refrigerant charged equipment.
!
Caution
Never add more than nameplate charge to the
refrigeration system for any application.
Ice Machine
Nameplate Charge
(Charge Shipped in Ice Machine)
Refrigerant to be Added for
50'-100' Line Sets
Maximum System Charge
(Never Exceed)
S500 6 lb. (96 oz.) 1.5 lb. (24 oz.) 7.5 lb. (120 oz.)
S600 6.5 lb. (104 oz) 1.5 lb. (24 oz.) 8 lb. (128 oz.)
S850 8.5 lb. (136 oz.) 2 lb. (32 oz.) 10.5 lb. (168 oz.)
S1000 8.5 lb. (136 oz.) 2 lb. (32 oz.) 10.5 lb. (168 oz.)
S1400 11 lb. (176 oz.) 2 lb. (32 oz.) 13 lb. (208 oz.)
S1600 11.5 lb. (184 oz.) 2 lb. (32 oz.) 13.5 lb. (216 oz.)
S1800 12.5 lb. (200 oz.) 1 lb. (16 oz.) 13.5 lb. (216 oz.)