Loading ...
Loading ...
Loading ...
33
ENGLISH
Connecting Electric Dryers (cont.)
USA only
w
WARNING






fire or death.





Three-wire connection for electric dryers: Direct wire







shape.

back of the dryer. Install a UL-listed strain relief into
the power cord through-hole; then thread the power


conductor cable.

and reinstallation of the dryer.

outer terminal block screws. Attach the neutral wire to
the center terminal block screw. Connect the external
ground (if required by local codes) to the green
ground screw. .
Reinstall the terminal block access cover.

UL-Listed
Strain Relief

Power Cord
Terminal

Ground
Screw
Neutral
(White)
Hot

Hot
(Red)
External Ground
Wire (If required
by local codes)
White Wire
from Dryer
harness
INSTALLATION INSTRUCTIONS
MFL67731059_en_170714.indd 33 2017.7.14 5:4:40 PM