Connecting Electric Dryers (cont.)
USA only
w
WARNING












Three-wire connection for electric dryers:
Power cord




upper back of the dryer. Install a UL-listed strain relief
into the power cord through-hole; then thread a UL-
listed, 
 conductor power cord through the strain
relief.

 conductor and closed loop or
forked terminals with upturned ends.

outer terminal block screws. Attach the neutral wire to
the center terminal block screw. Connect the external
ground (if required by local codes) to the green
ground screw. .
Reinstall the terminal block access cover.
UL-Listed
Strain Relief
UL-Listed

Cord
Terminal

Ground
Screw
Neutral
(White)
Hot

Hot
(Red)
External Ground
Wire (If required
by local codes)
White Wire
from Dryer
harness
INSTALLATION INSTRUCTIONS