10
Adaption to various types of gas APPLIANCE CATEGORY: II 2H3+
Energy consumption
Burner Gas Type
Pressure
(kPa)
Injector
(mm)
MJ/h
Small
(Auxiliary)
Natural
Propane
1.0
2.75
0.92
0.56
4.2
4.0
Medium
(Semi-rapid)
Natural
Propane
1.0
2.75
1.17
0.73
6.6
6.9
Large
(Rapid)
Natural
Propane
1.0
2.75
1.55
0.98
11.5
12.3
Wok *
Natural 1.0
inner 0.80
outer 2 x
1.14
15.6
Propane 2.75
inner 0.50
outer 2 x
0,73
17.0
Oven
Natural 1.0 1.80 16.0
Propane 2.75 1.10 16.0
Check correct operation of the ignition system and operation of burners individually
and in combination. Burner flames should be clear blue, with no yellow tipping. If the
burners show any abnormality check that burner heads are correctly located.
Note: These burners have no aeration adjustment.
Burner "MINIMUM" adjustment:
Work surface burner adjustment: follow the instructions below to adjust the work
surface burner minimum:
- Light the burner and set the knob to the MINIMUM position (small flame).
- Remove the knob of the valve that is press-fit on the rod of that valve.
- Insert a small slotted screwdriver into the hole on the valve body (Fig.10A) and
turn the choke screw to the right or left until the burner flame is adjusted to
minimum.
- For the gas valve of dual burner the choke valve is located on the valve body
(fig. 10B) , the A screw adjust the outer ring, the B screw adjust the inner ring.
- Make sure that the flame does not go out when switching quickly from the
MAXIMUM to the MINIMUM position.
Fig 10A Fig 10B
WARNING: The above-mentioned adjustment should be made only with natural gas
burners, while those operating with liquid gas the screw must be locked at the end
in a clockwise direction.
Test the operation of It should be noted that Bertazzoni SpA cannot accept any liability for direct or
the cooker before
indirect damage caused by incorrect connection or improper installation. When
leaving
being repaired, the appliance must always be disconnected from the mains supply; if
required, notify our customer service.
Loading ...
Loading ...
Loading ...