In no case should an inlet pipe less than 3/4” inside diameter or 1” outside
diameter ever be used to connect this product.
Calculate the total BTU output of all equipment and refer to (See Appendix “B” for
further details) for allowable run distances for 3/4 inch pipe. Failure to meet these
minimum requirements may reduce performance of the grill and any other
appliances running on that supply line.
Always keep supply line runs as short as possible. (See “Tables 1 and 2” for specific
model BTU outputs)
A gas shut-off valve must be installed in an easily accessible location by a qualified
gas technician.
Do not use threading compound on any flare fittings.
IMPORTANT:
Always close the gas supply shutoff valve before disconnecting the appliance’s
gas supply hose.
IMPORTANT:
An installer-supplied safety shutoff valve MUST be installed on the natural gas
supply line for the grill/side burner. The valve should be easily accessed and located between 3
and 20 feet (1 to 6 m) away from the appliance (always check with local codes for specified
clearances and distances). All gas connections should be made by a licensed technician. The
installation and all installer-supplied parts must conform to local codes. In the absence of local
codes, the installation and all parts should conform to the National Fuel Gas Code, ANSI Z223.1/
NFPA 54 or Natural Gas and Propane Installation Code, CSA B149.1.
IMPORTANT:
Diameter and length of the gas supply pipe may limit the pressure and BTU
delivery of gas to the oven. The installer must ensure proper delivery to the appliance or it will
not operate properly (See “Appendix B” for further details). The appliance and its individual
shutoff valve must be disconnected from the gas supply piping system during any pressure
testing of that system at pressures in excess of 1/2 psi (3.5 kPa). During any pressure testing of
the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa), the
appliance must be isolated from the system by closing its individual manual shutoff valve.
IMPORTANT:
Never run flex hose behind the firebox, run the hose at an angle, straight down,
or out of the back.
All pipe sealants must be of an approved type
.