5. Mount range hood. See the “Install Range Hood” section.
Install Range Hood Internal Blower Motor
1. Install the range hood blower motor assembly inside the
range hood canopy with the wiring connection to the left for
the single motor system and to the front or top for the dual
motor system.
Single Blower Motor Assembly
Dual Blower Motor Assembly
2. Slide the left mounting plate ange under the motor
mounting bracket.
3. Run the power supply wires and connector from the range
hood through the hole in the right end of the motor mounting
plate.
4. Push the right end of the motor mounting plate up and snap
it into the spring tab.
NOTE: The spring tab should be outside the slot in the
mounting plate.
A
A.Wiring connection
A
A.Wiring connection
BA
A. Motor mounting bracket
B. Mounting plate left ange
A
B
A. Motor mounting plate hole
B. Power supply wires and connector
A
B
A. Motor mounting plate
B. Spring clip
A
A
A
B
A. Clip nut locations for dual motor assembly (5)
B. Clip nut locations for single motor assembly (2)