11
Up-Front Air Filters
Two up-front filters, easy
to remove and reinstall,
may be cleaned without
removing the room front.
Clean by brushing,
vacuuming, or back
flushing under faucet or
shower head.
Easy Clean Air Discharge Area
2500 and 3500 series units have an out-of-sight vertical
protective screen over the indoor fan. This allows easy
cleaning of air discharge area by simply removing room
front and wiping clean.
There is no screen directly below discharge louver to trap
unsightly dirt and debris where it may be seen by room
occupants.
Concealed Manual Vent Control
Vent can allow up to 70 CFM
of outside air to enter the
room (40 CFM on 7100 BTUH
unit; 65 CFM on 9000 BTUH
unit; 70 CFM on 11700 BTUH
and 14600 BTUH units).
Greater amounts of air can be
introduced if the room has an
exhaust fan.
An open vent door brings unconditioned outdoor air into
the room, increasing heating and cooling costs.
Positive vent door closure prevents accidental opening and
unwanted air infiltration.
Shipping hardware may be left on the door for a permanent
closure.
Corrosion Protection (Optional)
2500 and 3500 series units may be ordered with special
protection to better withstand the damage by salt air and salt
water in seacoast areas.
Corrosion protected chassis is standard on Dry Air 25
models.
Heat Pump units with ICR are not available with corrosion
protection and should not be installed in seacoast or
corrosive environment.
Units installed in corrosive areas should be examined and
cleaned more frequently than normal installations.
Internal Condensate Removal (ICR)
See page 34 for a discussion of the Internal Condensate
Removal system available on the 3500 and 5500 series heat
pumps.
Enhanced Dehumidification
Moisture removal is an important function of an air
conditioner. People are more comfortable at higher
temperatures when the humidity level is relatively low.
Air conditioners operate with less energy consumption when
the room temperatures are set higher.
The GE Zoneline 2500 series with the Dry Air 25 heat pipe
application removes 25% more moisture than our base 2500
series unit - which is already an industry leader among the
major brands of Packaged Terminal Units.
The GE Zoneline Dry Air 25 chassis is the only unit available
with the application of the patented Dinh Dehumidifer Heat
Pipe under license from Heat Pipe Technology, Inc.
Customers who are using the Dry Air 25 report a fresher
smelling room as a result of the lower humidity levels - as
well as lower operating costs.
Locking Door Kit
RAK8022 - A door with a lock, that replaces the standard
control cover door to prevent unauthorized changing of
control setting, is offered as
an accessory.
2020 Data Manual 2002 11/7/02 3:19 PM Page 11