Elica ERS636S1 36 Inch Ducted Downdraft Hood

User Manual - Page 7

For ERS636S1.

PDF File Manual, 44 pages, Read Online | Download pdf file

ERS636S1 photo
Loading ...
Loading ...
Loading ...
7
Installation Instructions
Venting Methods
Determine which venting method is best for your application.
Vent system can terminate either through the wall or oor.
Island locations
Front (standard) mounted
blower motor
Rear mounted blower motor
(Reversible version)
C
B
A
C
B
A
A. Down vent
B. Cooktop
C. Aspiration plate
Built-in cabinet locations
A
B
C
A. Down vent B. Left vent C. Right vent
Island locations
Vent systems installed under a concrete slab using PVC sewer
pipe.
Front (standard) mounted blower motor
B
CM
A
L
K J I
H
G
E
F
D
Rear mounted blower motor (reversible aspiration plate)
B
D
E
F
G
H
IJK
A
M C
L
A. Wall cap
B. 6” (15.2 cm) round metal vent
C.16” (40.6 cm) maximum
D. 6” (15.2 cm) round PVC swer pipe
E. 6” (15.2 cm) round metal vent transi-
tion with damper (supplied)
F. 6” (15.2 cm) round PVC coupling
G. Concrete slab
H. 6” (15.2 cm) round PVC sewer pipe
I. 6” (15.2 cm) round 90º PVC sewer
pipe elbow
J. Tightly pack gravel or sand
completely around pipe
K. 6” (15.2 cm) round 90º PVC sewer
pipe elbow
L. 6” (15.2 cm) round PVC coupling
M. 12” (30.5 cm) minimum
Installing the vent system
WARNING
Excessive Weight Hazard
Use two or more people to move and install downdraft vent.
Failure to do so can result in back or other injury.
1. Place cardboard or similar material on top of a at surface where
you can easily assemble the downdraft vent system.
2. Remove parts packages, downdraft vent and blower box from the
carton.
3. Remove all shipping materials, tape and lm from the downdraft
vent and blower box.
4. Install the right and left undercounter mounting brackets to the
vent box. Slide the keyhole slots over the guide tabs and push
the brackets up to set them in place.
A
B
C
D
A. Vent box
B. Undercounter mounting bracket
C. Keyhole slots
D. Guide tabs
5. Attach the end cap to the vent box, depending on what vent
position you choose (standard-reversible). Place the tabs into the
mounting slots at each end of the downdraft vent as shown and
push down to lock into place.
A
B
A. Standard installation cap
B. Reversible installation cap
Loading ...
Loading ...
Loading ...