Elica ERS636S1 36 Inch Ducted Downdraft Hood

User Manual - Page 12

For ERS636S1.

PDF File Manual, 44 pages, Read Online | Download pdf file

ERS636S1 photo
Loading ...
Loading ...
Loading ...
12
Control connection
1. Run the control wire from the motor box to the location of the
control assembly (see the image below).
A
B
C
A. Control
B. Adhesive wire clips
C. Control connection wire
NOTE: It is recommended to guide the connection wire as close
as posible to the motor box, avoiding to get the wire loose. Use the
provided adhesive wire clips.
2. Plug both wire connectors.
A
B
A. Control wire
B. Motor box wire
3. Check the operation.
Installing the Top trim
1. Push down the top trim against the downdraft top. The top trim’s
pins must enter into the downdraft plastic clips.
Check operation
1. Push and hold the control button for a few seconds. The
retractable section of the downdraft vent will rise, and the blower
will start. Position the top trim over the retractable section and
snap trim into place.
A
B
C
D
E
A. Top trim
B. Aspiration plate
C. Grease lters
D. End cap
E. Control
2. If the blower does not operate:
• Check that aspiration plate is pressed in as far as they will go.
• Check that the circuit breaker has not tripped or a household
fuse blown.
3. Connect vent system to blower. Vent system must end with a
wall or roof cap. Use clamps or duct tape to seal all joints.
4. Install cooktop according to manufacturer’s instructions.
VENT SYSTEM USE
The retractable downdraft vent system is designed to remove
smoke, cooking vapors and odors from the cooktop area.
• For best results, the vent should be operating before cooking is
started.
• If you use large or tall utensils, place them on the large rear
element or burner surface.
• A higher heat setting than normally used may be needed when
the downdraft vent is operating.
• For gas cooktops, the downdraft vent system may affect the
ame stability and cooking performance. To improve the burner
performance, either decrease the downdraft vent blower speed or
increase the cooktop burner ame setting.
• For gas cooktops with ame sensing ignitions, the downdraft vent
system may disperse the ame away from the spark igniter and
may cause it to continually spark while trying to reignite a burner
that is already lit. To resolve the issue of the cooktop igniter
continuously sparking, either decrease the downdraft vent blower
speed or increase the cooktop ame setting for that burner.