Loading ...
Loading ...
Loading ...
Installation
58
Burner and nozzle specifications tables
1 Natural gas G20 – 20 mbar SR R UR
Rated heating capacity (kW)
1.7 3.1 6.0
Nozzle diameter (1/100 mm)
92 126 175
Reduced flow rate (W)
500 900 1800
Primary air (mm)
111
2 Natural gas G20 – 25 mbar SR R UR
Rated heating capacity (kW)
1.7 3.1 5.7
Nozzle diameter (1/100 mm)
87 120 160
Reduced flow rate (W)
500 900 1800
Primary air (mm)
111
3 Natural Gas G25 – 25 mbar SR R UR
Rated heating capacity (kW)
1.7 3.1 6.0
Nozzle diameter (1/100 mm)
95 130 185
Reduced flow rate (W)
500 900 1800
Primary air (mm)
110.5
4 Natural gas G25.1 – 25 mbar SR R UR
Rated heating capacity (kW)
1.7 3.1 5.9
Nozzle diameter (1/100 mm)
98 135 190
Reduced flow rate (W)
500 900 1800
Primary air (mm)
110.5
5 Natural Gas G25 – 20 mbar SR R UR
Rated heating capacity (kW)
1.7 3.1 6.0
Nozzle diameter (1/100 mm)
100 140 200
Reduced flow rate (W)
500 900 1800
Primary air (mm)
110.5
6 Natural Gas G27 – 20 mbar SR R UR
Rated heating capacity (kW)
1.7 3.1 5.8
Nozzle diameter (1/100 mm)
105 145 200
Reduced flow rate (W)
500 900 1800
Primary air (mm)
10.50.5
7 Natural gas G2.350 – 13 mbar SR R UR
Rated heating capacity (kW)
1.7 3.1 6.0
Nozzle diameter (1/100 mm)
126 175 280
Reduced flow rate (W)
500 900 1800
Primary air (mm)
113